Electric Heating Circulating Oven

The electric heating circulating oven generates heat through resistance wires and, in conjunction with a fan, circulates hot air within the chamber to evenly heat samples. It is used for processes such as material drying, curing, and heat treatment, and is suitable for laboratory and production environments in industries such as coatings and plastics.
Selection
When selecting, consider the temperature range and uniformity, corrosion resistance of the inner chamber material, fan circulation efficiency, temperature control accuracy, and safety protection functions. Match the volume and size according to the characteristics of the samples, and determine whether to use natural convection or forced air circulation based on energy consumption and usage scenarios.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Mirror stainless steel liner and electric heating film heating, Temperature Uniformity +/- 1 ℃, heating speed, double-decked door design to reduce heat loss, four corners arc easy to clean.

$ 601.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Mirror stainless steel liner and diagonal air duct structure, Temperature Uniformity up to +/- 1 ℃, electric heating film heating rapid heating, double-decked door design to reduce heat loss, independent temperature limit alarm to ensure experimental safety.

$ 509.00

Using fuzzy PID controller to achieve accurate temperature control, Temperature Fluctuation +/- 0.5 ℃; Forced convection air duct system to improve Temperature uniformity; Mirror stainless steel liner with electric heating film heating, rapid and uniform heating; Independent temperature limit alarm to ensure experimental safety.

$ 992.00

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

Heating mode heating speed, temperature control accuracy of +/- 0.2 ℃, equipped with double-decked door structure and mirror stainless steel liner, support RS485 interface connection recording equipment.

$ 854.00

Temperature range environment to 380 ℃, can work continuously, large heating area and rapid heating, effectively protect Glass ware.

$ 140.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the heating is fast, the maximum operating temperature is 380 ℃, and the hemispherical internal thermal design avoids the danger of open flame.

$ 212.00

The fully enclosed heating plate is designed without open flame, Heating power 3000W, heating up quickly and safely, and the studio stainless steel material has superior corrosion resistance.

$ 236.00

Fuzzy PID controller is used to ensure accurate temperature fluctuation, forced convection duct to raise Temperature uniformity to +/- 1.5 ℃, automatic control of circulating fan speed to avoid sample volatilization, mirror stainless steel liner and electric heating film Heating mode to achieve rapid and uniform heating.

$ 804.00

Using high temperature non-alkali fiberglass insulation material sealing resistance wire, large heating area and heating fast, the highest temperature 380 ℃, support internal and external dual Sensor temperature measurement, no open flame design to avoid bumping Glass ware.

$ 170.00

Rotation speed 3000rpm, maximum linear speed 33m/s, high dispersion efficiency, strong material shear force, the formation of uniform suspension effect, safe and convenient operation, electric lifting fast fixed sealing barrel.

$ 2676.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.