Guide to Avoiding Pitfalls in Selecting Laboratory Ovens

This article outlines the key points for selecting a laboratory electric thermal convection drying oven. By heating air and employing forced convection, the oven achieves drying, curing, or aging of samples. During selection, attention should be paid to temperature uniformity, heating rate, ventilation efficiency, and price differences, avoiding confusion with constant temperature and humidity chambers or vacuum drying ovens. The article also provides practical application cases in industries such as automotive, pharmaceuticals, and polymer materials, emphasizing the critical impact of temperature uniformity on experimental results.

2026-07-09

Technical Principle and Application of the Paint Film Cupping Tester

The cupping tester for paint films is a critical testing device for evaluating the flexibility and adhesion of coatings, and is widely used in fields such as automotive coatings, coil coatings, and appliance coatings. This article systematically describes the working principle, structural composition, and technical parameters of the cupping tester, and analyzes its essential differences from the metal cupping tester. Based on standards such as GB/T 9753-2007 and ISO 1520, the testing methods, result evaluation, and influencing factors are discussed. Research shows that the cupping tester quantifies the crack resistance and peel resistance of coatings by simulating the deformation process of the coating along with the substrate through the cupping index, which holds significant guiding value for coating development and coating quality control.

2026-07-06

Conversion relationship between edge crush strength and box compression strength

This article introduces the relationship between the edge crush strength of corrugated cardboard and the compression strength of cartons. Edge crush strength is an indicator of cardboard performance, while compression strength is an indicator of the structural performance of finished cartons. The two are converted through an empirical formula. The article explains the principle of the simplified formula, measurement methods, and demonstrates the calculation process with specific examples. It also analyzes the impact of factors such as printing, openings, and humidity on the conversion results.

2026-06-30

Correction Method for Whiteness Measurement Values Affected by Fluorescent Brighteners

This article discusses the influence of fluorescent whitening agents on measured paper brightness values and corresponding correction methods. Fluorescent whitening agents absorb ultraviolet light and emit blue light, resulting in inflated brightness measurements. Correction methods are categorized at the instrument level and the data processing level: the former involves eliminating or standardizing UV light to measure the true substrate brightness, while the latter uses spectral conversion or mathematical modeling to eliminate fluorescence-induced deviations. The article also compares the applicable scenarios and limitations of different correction methods, addressing issues such as brightness values exceeding 100% and instrument variability.

2026-06-30

Selection principles of 75° and 20° angles in gloss testing

This article describes the principles for selecting different measurement angles in gloss testing. The measurement angle affects the readings: 60° is the general-purpose angle suitable for most materials; if the 60° reading exceeds 70 GU, switch to the 20° angle; if it falls below 10 GU, switch to the 85° angle. Additionally, the paper industry also uses 20°, 45°, and 75° angles. Testing should begin with the 60° angle as a judge, then change angles based on the results, while ensuring the sample surface remains clean.

2026-06-30

Matching of Loading Speed and Fracture Time in Tensile Strength Test

This article discusses the matching relationship between loading speed and breaking time in tensile strength testing. The standard requires the specimen to break within 20±5 seconds to ensure measurement accuracy. Loading too fast or too slow can affect the results—for example, too slow may cause creep effects, while too fast may lead to shear fracture. The article also introduces standard tensile speeds for different materials, as well as the impact of factors such as temperature, humidity, and clamp position on test results.

2026-06-30

Selection principles for the clamping gap distance of the MIT folding endurance tester

This summary introduces the selection principle for the jaw gap distance of the MIT folding endurance tester. The jaw gap refers to the opening width between the two clamping plates in the folding head, typically available in four specifications: 0.25, 0.50, 0.75, and 1.00 millimeters. The selection is primarily based on the actual measured thickness of the specimen, rather than its nominal grammage. The principle is that the jaw gap should be slightly larger than the specimen thickness, ensuring free folding while avoiding errors caused by excessive tightness or looseness. Different thicknesses correspond to different jaw gaps. During operation, the corresponding jaw must be replaced, and it is necessary to check whether the folding mark is centered.

2026-06-30

Range selection of Taber stiffness tester for paperboards of different thicknesses

This article, titled "Range Selection of Taber Stiffness Tester for Paperboards of Different Thicknesses," primarily introduces the method for selecting the range of the Taber stiffness tester. It begins by explaining the concept of the range and points out that the instrument is suitable for paperboards with a thickness of 0.1 to 5.5 millimeters, though stiffness and thickness have a nonlinear relationship. The article then mentions the principles for range selection as specified by national and international standards, noting that the Taber method is suitable for medium-to-high stiffness paperboards, while low-stiffness thin paper requires other methods. During operation, it is recommended that readings fall between 20% and 80% of the full scale; otherwise, adjustments are necessary. The article also provides reference ranges for different paperboard thicknesses and emphasizes the need for calibration after changing the range, along with regular maintenance of the pendulum.

2026-06-30

Differences between puncture strength and burst strength in dynamic impact evaluation

This article mainly explains the differences between the puncture resistance and bursting strength of paperboard. Bursting strength is a static loading test that measures the ability of paperboard to withstand slow and uniform pressure, while puncture resistance is a dynamic loading test that simulates sudden impact. The two have different physical meanings: bursting strength is measured in units of pressure, whereas puncture resistance is measured in units of energy. The testing methods and standards also differ—puncture resistance involves the potential energy of a pendulum, while bursting strength uses hydraulic or pneumatic pressure. Although there is a certain correlation between the two, they cannot replace each other. Domestic light industry standards have removed the puncture resistance requirement, but export box inspections still retain this requirement.

2026-06-30

Operating Specification for Short-Span Compression Tester in Corrugating Medium Evaluation

This article introduces the operating method of short-span compression testing in the evaluation of corrugating medium. By utilizing a 0.7 mm short-span design, it eliminates bending effects and directly measures the compressive strength of the paper. The article covers the principle of the method, the basis of ISO and national standards, operational steps, and solutions to common issues such as specimen slippage, skewed fractures, and jaw wear. This method is suitable for materials like corrugating medium and linerboard, and is used for quality control and predicting the strength of finished products.

2026-06-30

Application of Bentsen Roughness Tester in the Printability of Coated Paper

This article introduces the application of the Bendtsen roughness tester in the printability of coated paper. It measures the surface roughness of paper using the air-leak method: air leaks through the gap between the measuring head and the paper surface, with a higher flow rate indicating greater roughness. The article mentions that the smoothness of coated paper is influenced by pigment particle size, coating process, and calendering treatment, directly affecting ink transfer and dot accuracy. The Bendtsen method is easy to operate, shows good correlation with printing results, and can be used for quality control and process optimization. Testing must follow national standards and is applicable to most coated papers, but it is not suitable for soft or porous paper types, and it can be used complementary to the PPS method.

2026-06-30

Applicability of the Gurley Porosity Tester in Corrugating Medium Testing

This article explores the applicability of the Gurley porosity tester in testing corrugating medium. The Gurley method evaluates air permeability by measuring the time it takes for air to pass through a sample and is suitable for paper and paperboard with an air permeance ranging from 0.1 to 100 µm/(Pa·s). However, it is not suitable for materials with rough surfaces, such as corrugating medium, because the clamps fail to seal properly, leading to air leakage. Alternative methods include the Bendtsen method and the Schopper method. Tests require conditioning for 48 hours under standard conditions. Common issues include that stacking layers does not improve sealing, and automatic instruments are equivalent to manual ones. A method is also provided to determine whether the corrugating medium is suitable for testing.

2026-06-30

Application of Washability Tester in Evaluating Scrub Resistance of Architectural Coatings

This article introduces how the washability tester is used to evaluate the scrub resistance of architectural coatings. It details the testing principle, simulating the mechanical motion of manual scrubbing to quantify the durability of the coating, and lists the equipment composition, testing standards, application cases, and key factors affecting the results. The article emphasizes that standardized operation can provide reliable comparative data, but test results cannot be directly equated with actual service life and must be comprehensively analyzed in conjunction with other performance indicators.

2026-06-23

Application of Rotational Viscometer in Evaluating Rheological Properties of Coatings

This is an article introducing the application of rotational viscometers in evaluating the rheological properties of coatings. The article first explains the non-Newtonian fluid characteristics of coatings, illustrating that traditional single-point viscosity measurements are not comprehensive. It then introduces the working principle of rotational viscometers, along with key measurement parameters such as yield stress, shear-thinning index, and thixotropy. Relevant testing standards and specifications are also mentioned, with practical application examples provided for water-based architectural coatings and industrial anti-rust paints. Finally, the article analyzes common sources of error and data processing methods, and anticipates the development trend of instruments toward digitalization and online monitoring.

2026-06-23

Application of Coating-4 Viscometer in Measuring Construction Viscosity of Coatings

This abstract introduces the application of the TU-4 viscometer in determining the construction viscosity of coatings. The measurement principle is based on the fluid dynamics capillary outflow method, recording the time for the coating to flow out of a standard orifice. Operation details such as temperature and bubble control are required to ensure data reliability. Results are influenced by factors including temperature, rheological properties, and instrument accuracy. The article also provides examples from scenarios such as architectural, automotive, and wood coatings, emphasizing the importance of sample handling, environmental control, and instrument calibration for error minimization.

2026-06-23

Application of Magnetic Thickness Gauge in Non-Destructive Measurement of Paint Film Thickness on Steel Substrates

This article introduces the principle, application scope, operational key points, and calibration methods of magnetic thickness gauges for measuring paint film thickness on steel substrates. It measures non-magnetic coating thickness through changes in the magnetic field, and is widely used in industries such as automotive, shipbuilding, and pipeline. Before measurement, the surface must be cleaned, the probe must be perpendicular to the surface, and the median should be taken from multiple measurements at the same position. Calibration requires steel substrates of the same grade and standard foils. Errors may arise from substrate thickness, surface roughness, or temperature variations. The article also illustrates, through examples in bridge and ship applications, the need to consider substrate conditions and environmental factors in actual practice. The method is limited to ferromagnetic substrates, and repeatability is poor for thin coatings. Future trends include probe miniaturization and intelligent algorithms.

2026-06-23

Application of Thermogravimetric Analyzer in Determination of Solid Content and Flame Retardant Content in Coatings

This article introduces the application of thermogravimetric analyzers in the testing of coatings. It first explains the importance of solids content and flame retardant content for coating performance, noting that traditional testing methods are time-consuming and prone to significant errors. Through programmed temperature control to monitor sample mass changes, thermogravimetric analysis can measure these two parameters in a single test, in compliance with domestic and international standards. The article elaborates on the principles, experimental procedures, and influencing factors, and verifies the accuracy of the method using specific case studies. Compared to traditional methods, thermogravimetric analysis is faster and has lower deviations, but it cannot distinguish between mass loss from different components within the same temperature range. Finally, the article looks forward to the prospects of this technology in the coatings industry.

2026-06-23

Application of Differential Scanning Calorimetry in Analyzing Glass Transition Temperature and Curing Degree of Coatings

This article introduces the application of differential scanning calorimetry in coating analysis, focusing on the measurement of glass transition temperature (Tg) and degree of curing. The glass transition temperature reflects the point at which the coating transitions from a glassy state to a high-elastic state, affecting the flexibility and hardness of the coating film. The degree of curing, on the other hand, calculates the extent of crosslinking completion through exothermic reactions, helping to optimize the baking process. The article also discusses factors affecting test results, such as heating rate, sample mass, and atmosphere, and provides examples of the actual application of this technology in formula development, failure analysis, and process improvement. Future trends include modulated differential scanning calorimetry, online monitoring, and hyphenated techniques to improve measurement accuracy and process control capabilities.

2026-06-23

Application of Karl Fischer Moisture Titrator in the Precise Determination of Moisture Content in Coatings

This article introduces the application of the Karl Fischer moisture titrator in the detection of moisture in coatings. The principle is based on the reaction of iodine and sulfur dioxide with water molecules in a specific medium. The endpoint is detected by electrodes, enabling precise moisture measurement and avoiding interference from volatile solvents. Sample preparation requires uniform stirring, and high-viscosity coatings can be diluted with anhydrous solvents. The instrument must be equipped with a drying tube and a sealed titration cell; for complex matrices, specialized reagents should be used. Case analysis shows that this method is more accurate and faster than the traditional oven-drying method, effectively reducing the misjudgment rate. During use, attention should be paid to interference from alkaline or acidic components and aldehydes or ketones, while also controlling the temperature and regularly verifying with standard substances. Future trends point toward automation and online monitoring to enhance production efficiency.

2026-06-23

Application of UV-Vis Spectrophotometer in Determining Hexavalent Chromium Content in Coatings

This article introduces the method for detecting hexavalent chromium content in coatings using a UV-Vis spectrophotometer. The principle is based on the reaction of hexavalent chromium with diphenylcarbazide to form a purple-red complex, with absorbance measured at a wavelength of 540 nm. The article details sample pre-treatment, instrument operation, common interference elimination (e.g., iron ions, vanadium ions), and data quality control methods, while also validating the reliability of the method through practical case studies. Key points include alkaline digestion extraction, fresh preparation of the chromogenic reagent, spiked recovery, and reduction control experiments.

2026-06-23