304 stainless steel one-time stretching liner has no water leakage, the four-corner arc design is heated evenly, the temperature fluctuation is +/- 0.5 ℃, the six-hole configuration meets various experimental needs, and the hidden outlet pipe is easy to operate.
Using stainless steel liner, beaker hole can be arbitrarily changed size, temperature control accuracy +/- 0.5 ℃, with over-temperature sound and light tracking alarm function to ensure the safety and reliability of the sample.
Using stainless steel liner, beaker hole can be arbitrarily changed size; temperature control accuracy of +/- 0.5 ℃, with over-temperature sound and light tracking alarm function to ensure sample safety.
Temperature control accuracy of +/- 0.5 ℃, Temperature resolution of 0.1 ℃, with over-temperature sound and light alarm function, stainless steel liner can adapt to different beaker sizes, support internal and external circulation, ensure sample safety and stability.
Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.
Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.
Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.
Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with a built-in circulating water pump to output thermostatic water flow, stainless steel structure to ensure durability and easy cleaning.
Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.
The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.
304 stainless steel one-time stretch forming liner, no water leakage; four-corner arc design to ensure temperature uniformity; temperature control accuracy of +/- 0.5 ℃, heating power 600W, to meet the long-term stable thermostatic needs.
With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.
With three sets of independent water Tanks and temperature control equipment, temperature can be set separately, temperature control accuracy +/- 0.3 ℃, resolution 0.1 ℃, stainless steel liner anti-corrosion easy to clean, over-temperature sound and light alarm to protect the sample.
304 stainless steel one-time stretching liner, no leakage; four-corner arc design to avoid temperature control dead angle, to ensure the uniformity of water temperature; temperature control accuracy of +/- 0.5 ℃, volume 13L.
Temperature control accuracy +/- 0.3 ℃, resolution 0.1 ℃, mirror stainless steel liner for easy cleaning, silicone sealing ring to ensure high sealing, microcomputer controller provides stable and reliable operation.