Liquid Electronic HydroMeter

The liquid electronic densimeter calculates density by measuring the buoyancy of the liquid or changes in vibration frequency. It is used to detect the concentration and purity of liquids such as coatings and inks, and to monitor liquid composition in production and quality inspection processes.
Selection
When selecting, consider the measurement range matching the sample density, ensuring accuracy meets detection requirements, and compensating for sample temperature effects. The operating environment should be adaptable to both laboratory and field conditions, with instrument materials resistant to corrosion, and calibration and maintenance should be convenient.
material
Cup volume
Calibrated certificate

Terms

Standards

Instruments

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

Density direct reading function eliminates the calculation step, can measure solid and liquid density, accuracy of 0.01g, Repeatability +/- 0.01g, all aluminum base design enhances weighing Stability.

$ 415.00

Density direct reading function eliminates calculation steps, can measure solid and liquid density, accuracy to three decimal places, equipped with display shield and all aluminum base, enhanced dust and Stability.

$ 680.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, supports liquid Density measurement and custom setting of Density upper and lower limits, and standard RS232 interface is convenient for data transmission.

$ 496.00

Using Electromagnetic Force Sensor to ensure data accuracy, density Measurement range 0~ 10g/cm ³, resolution 0.0001g/cm ³, large sink glass to reduce errors, built-in a variety of liquid density values, under the dish weighing design anti-spill.

$ 754.00

Adopting the principle of U-tube vibration method, Sensitivity up to 0.0001g/cm ³, equipped with automatic sampling system and Peltier thermostatic control to ensure measurement accuracy and Repeatability, support automatic cleaning to avoid residual effects.

$ 4124.00

Sensitivity, density resolution of 0.0001g/cm ³, repeatability error of 0.0003g/cm ³, automatic sampling and thermostatic control functions, built-in memory chip can save 80 sets of data.

$ 5261.00

Using double U-tube resonance principle and Thermostatic Bath control, Measurement accuracy of +/- 0.001g/cm ³, sampling only 2ml, support automatic sampling and 80 data storage functions.

$ 3193.00

Using electronic control liquid crystal display, automatic swirl/spin test operation is convenient, the accuracy is 0.01mm, the effective range of the special fixture is 0-30mm to ensure that the bottle body is not deformed, and the platform stability testing results are accurate.

$ 1108.00

Temperature range environment temperature to 380 ℃, can work continuously. The surface temperature of the heating element is up to 380 ℃, and the insulating layer is wOven with high temperature resistant fiberglass without alkali.

$ 117.00

Temperature range environment to 380 ℃, can work continuously, large heating area and rapid heating, effectively protect Glass ware.

$ 140.00

Temperature range environment temperature to 380 ℃, can work continuously, heating element surface temperature up to 380 ℃, insulation layer sealing resistance wire design is safe and reliable.

$ 110.00

Temperature range environment temperature to 380 ℃, can work continuously, the maximum temperature of the surface of the heating element is 380 ℃, and the sealing design of the insulating layer ensures the safety of use.

$ 114.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.