Fully Automatic Moisture Analyzer

The automatic moisture analyzer evaporates moisture by heating the sample and calculates the water content by measuring the weight loss. It is used for rapid detection of moisture content in materials such as coatings and plastics, replacing manual operations to reduce errors.
Selection
When selecting, focus on matching the sample characteristics with the heating method, consider the requirements for detection accuracy and speed, verify the sample capacity specifications, check compliance certifications, and evaluate equipment maintenance costs and operational complexity.

Terms

Standards

Instruments

Fully automatic heating cabin door dual-drive ultra-quiet opening, 230 ℃ limit heating temperature to meet most sample tests, equipped with imported HBM weighing Sensor and four stainless steel heating cabin, Capacity 110g, moisture readability of 0.01%.

$ 1171.00

Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.

$ 1332.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

The fully automatic electronically controlled hydraulic pump provides smooth and continuous pulling force with +/- 1% accuracy, built-in rechargeable battery supports 200 tests, and IP65 Protection Rating ensures durability.

$ 4212.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Moisture is measured by thermogravimetry, equipped with 500W high-efficiency halogen ring lamp for uniform heating, Temperature range 40-180 ℃ controllable. 5-inch Touchscreen real-time display of moisture change Linear dispersion, support automatic shutdown and Data storage 100 groups, intuitive operation without supervision.

$ 420.00

Adopt full Chinese display system, measurement accuracy ≤ +/- 0.5%, repeability ≤ +/- 0.2%, with automatic temperature compensation and bulk density conversion function, quickly complete moisture detection within 10 seconds.

$ 215.00

Automatic heating cabin dual drive ultra-quiet open, 230 ℃ limit heating temperature, 35cm sample placement height, 20 sets of storage addresses and test records, 7 inch high definition touch screen real-time display moisture percentage.

$ 2655.00

Automatic dual drive heating cabin door avoids human interference, 230 ℃ limit heating temperature meets most samples, 0.001g High Accuracy weighing and 35cm heating cabin height improve test efficiency, 7 inch touch screen real-time display Linear dispersion and data.

$ 2817.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Using constant current polarization detection technology, Measurement range 1μg-100mgH2O, accuracy of 0.1μgH2O, with automatic fault detection and dual-channel isolated power supply, effectively improve the test Stability and accuracy.

$ 5399.00

Ring halogen lamp heating, 0.02% moisture readability, RT +~ 180 ℃ Temperature range, automatic measurement, Draft Shield design, pure stainless steel heating Chamber cover, 16 sets of Data storage.

$ 503.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.