Moisture Measurement Drying Oven

The moisture determination drying oven evaporates moisture from samples by heating them and calculates the moisture content using the weight loss method. It is used for moisture testing of materials such as coatings and plastics to ensure process stability.

Instruments

The annular halogen lamp uniformly heats the sample, Capacity 50g, Moisture measurement range is 0.00~ 100%, and the measurement is completed within a few minutes. The results are consistent with the Oven method and the efficiency is higher.

$ 319.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

Using conductivity Measurement principle, can measure 0~ 80% moisture range, accuracy +/- (0.5% n + 1), with 240 data storage and USB/RS-232/Bluetooth communication function.

$ 235.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Using halogen radiation heating technology, the moisture readability reaches 0.01%, the determination of Precision +/- 0.2%, and the test is completed quickly in a few minutes, with 8 kinds of paraMeter display functions.

$ 446.00

Can store 240 sets of data, Measurement range 0-100%, provide a variety of measurement code selection, support LED status indication and LCD digital display, easy to accurately determine the moisture status.

$ 241.00

With needle and inductive two measurement modes, the measurement range is 0-80% and 0-70% respectively, accuracy +/- (0.5% n + 0.5), support USB, RS-232 and Bluetooth multiple data interfaces, equipped with color coded LED real-time display moisture status.

$ 275.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Ring halogen lamp heating to ensure uniform and fast drying of samples, Capacity 50g, Measurement accuracy 0.01%, support 0~ 99 minutes timing, 9 kinds of paraMeter display, suitable for solid, particle and other Sample types.

$ 344.00

Ring halogen lamp heating, 0.02% moisture readability, RT +~ 180 ℃ Temperature range, automatic measurement, Draft Shield design, pure stainless steel heating Chamber cover, 16 sets of Data storage.

$ 503.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.