Conductivity pen for water quality testing

The conductivity pen reflects the purity of water by measuring the conductive ability of ions in water; pure water has low conductivity, while water containing impurities has high conductivity. It is used for rapid detection of ion content in drinking water, industrial water, and laboratory water samples.
Selection
Select the range based on testing requirements, typically 0-2000 μS/cm for routine water quality; consider temperature compensation functionality; check the durability of the electrode material; confirm the availability of calibration solutions; and pay attention to the waterproof rating and power supply method.

Terms

Standards

Instruments

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Can simultaneously measure 10 water quality indicators, including pH, ORP, conductivity, etc., with IP67 waterproof and automatic temperature compensation function, data storage capacity of 45,000, adapt to harsh environment measurement needs.

$ 3373.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

Measurement range 2-3000uS/cm, Glass shell structure, three-core air interface, suitable for water quality analysis applications.

$ 114.00

Integrate 8 water quality paraMeter measurement functions, support automatic temperature compensation and calibrated reminders, equipped with 500 sets of data storage capacity, and adopt multi-mode power supply scheme to ensure long-term outdoor use.

$ 909.00

With conductivity 0~ 19.99mS/cm Measurement range, accuracy +/- 1.0%, support TDS conversion factor and temperature compensation settings. Platinum-plated black ElectRode reduces Polarization effect, IP67 Protection Rating is suitable for use in a variety of environments.

$ 155.00

With pH, conductivity, TDS and temperature Multi-ParaMeter measurement, pH range 0.0-14, EC range 0-3999 μS/cm, supports Automatic calibration and continuous monitoring, waterproof design and large screen display for easy operation.

$ 538.00

Support pH, conductivity, TDS and other seven paraMeter measurement, Data storage 450 groups, with automatic temperature compensation and ElectRode diagnostic function, dustproof and waterproof grade IP54, Measurement accuracy of +/- 0.01pH.

$ 772.00

With conductivity 0-2000mS/cm and dissolved oxygen 0-20mg/L wide range measurement, support automatic temperature compensation and air pressure compensation, 3.5 inch color screen display, data storage capacity of 3000 groups, Protection Rating is IP57.

$ 670.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

12 water quality paraMeters can be measured simultaneously, with IP67 waterproof rating and 45,000 data storage capacity, support automatic temperature compensation and fast calibrating, with backlit graphic display and intuitive Operating interface.

$ 2949.00

Platinum Sensor ensures fast and stable measurement, supports 1-3 point calibrate and 0.1-1 adjustable TDS conversion factor, with automatic temperature compensation and end point locking function, Measurement range covers 0-20mS/cm conductivity and 0-10ppt salinity.

$ 165.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Articles

Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Classification standards for determining the hardness of coatings using a pencil hardness tester.
This article introduces the method of measuring the hardness of coatings using a pencil hardness tester. It involves using pencils of varying hardness to scratch the coating and observing whether scratches are produced to determine the hardness grade, ranging from 6B to 9H.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Key Operational Points and Influencing Factors of Pencil Hardness Method for Determining Coating Film Hardness
The pencil hardness test is a method used to evaluate the scratch resistance of a coating by making marks on the paint film with pencils of known hardness. During the operation, a uniformly cured sample is prepared, and calibrated pencils are used to make marks at a 45-degree angle with a fixed force, aiming to identify the highest hardness grade that does not scratch through the paint film.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.