Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.
Adopt low noise fan and air duct to form hot air circulation system, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%, Inner Chamber dimensions 1000 × 800 × 800mm, shelf height and quantity can be adjusted, equipped with double-decked tempered Glass observation window.
Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Suitable for low and medium Hardness material measurement, pressure needle end pressure 0.55N-8.06N, pressure needle stroke 0-2.5 mm, can be matched with test rack to reduce manual operation error, improve test accuracy and Repeatability.
The imported central guide Rod material has high accuracy and abrasion resistance, the shell is made of super hard aluminum material to resist on-site damage, and the external spring coil pointer slider structure is easy to adjust the friction force. The nominal kinetic energy is 2.207J, and the strength measurement range is 20-60Mpa.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, hot air circulation system consists of low noise fan and air duct, the height and number of shelves in the studio can be adjusted, double-decked tempered Glass observation window is convenient for observing samples.
The dual-channel interface can connect two Probes at the same time, support K-type -200~ 999.9 ℃ wide range, with low power error-proof system and data locking function, waterproof design to adapt to a variety of environments.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with hot air circulation system and double-decked tempered Glass observation window, adjustable number of studio shelves height, support independent temperature control.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%, equipped with hot air circulation system, adjustable height and number of studio shelves, double-decked tempered Glass observation window for easy observation of sample status.
Temperature range RT + 5~ 300 ℃, Temperature Accuracy +/- 1 ℃, equipped with hot air circulation system and independent temperature controller, adjustable height of studio shelf, double-decked tempered Glass observation window for easy observation.