Infrared Imaging Camera

Infrared imaging thermal cameras detect infrared radiation emitted from the surface of objects and convert it into temperature distribution images. They are used to identify equipment overheating, detect material defects, and monitor production processes. In the industrial field, they assist in locating fault points, evaluating coating uniformity, and monitoring reaction temperatures.
Selection
Select the detector type based on the target temperature range, consider the spatial resolution to match the size of the object being measured, and pay attention to thermal sensitivity to ensure the ability to identify temperature differences. Choose the protection level according to environmental conditions, and determine the image frame rate and analysis functions based on usage requirements.

Terms

Standards

Instruments

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Built-in mobile slide table can move the camera front and rear, high display finger no stroboscopic LED Illuminant Color temperature is stable, the illuminance is adjustable, the back plate of the box can post 712mm * 400mm test card to provide a uniform lighting environment.

$ 4592.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

With camera viewing function to prevent measurement deviation, Repeatability Standard Deviation Delta E * ab within 0.05, dual Measurement mode synchronously displays SCI and SCE results, large storage space can store 20,000 data.

$ 3543.00

Image analysis method, support high temperature sample testing, camera resolution of 1280 × 1024, with dynamic contact angle analysis and surface energy estimation function, Measurement range 0~ 180 °, accuracy 0.01 °.

$ 2082.00

Test accuracy of 0.01 ° using image analysis method, support high temperature sample measurement, dynamic contact angle analysis and surface energy estimation function, camera resolution 1280 × 1024, Measurement range 0-180 °.

$ 3507.00

Support HDMI, WIFI and SD card three output, 1920 * 1080 resolution, can directly control camera paraMeters through USB mouse, embedded image capture and video recording, suitable for a variety of detection scenes.

$ 1461.00

Built-in camera to accurately locate the measurement area, UV Illuminant can measure fluorescent color, Repeatability Delta E * ab ≤ 0.06, supports 26 kinds of Illuminant and 30 + kinds of chroma indicators to meet various measurement needs.

$ 1929.00

Adopt D/8 lighting observation conditions, the measurement diaMeter is Φ 10mm, and the spectral reflectance Repeatability Standard Deviation is within 0.08%. It has camera framing and automatic Gloss compensation technology to ensure measurement accuracy.

$ 2849.00

High-resolution digital camera to achieve automatic detection, can simultaneously measure five capillary tubing, temperature range RT +~ 400 ℃, with automatic measurement and manual visual measurement function, support multi-point calibrating and data export.

$ 4874.00

Built-in camera to accurately locate the measurement area, equipped with UV Illuminant to achieve fluorescent color detection, Repeatability Delta E * ab ≤ 0.06, supports more than 30 chroma indicators and 26 Illuminant conditions, data can be shared through the cloud.

$ 1397.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

Using high-resolution video camera technology to replace the traditional Microscope, the temperature range is from room temperature to 350 ° C, and 4 samples can be processed simultaneously, compatible with powder and block sample measurement. Temperature resolution reaches 0.1 ° C.

$ 2010.00

Adopt high definition camera to observe the measurement process in real time, dual-channel simultaneous detection, adjustable heating rate 0.1-20 ℃/min, support video playback and automatic interpretation of deformation characteristics.

$ 5883.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
Coating Distinctness of Image (DOI) Meter Evaluates Surface Imaging Clarity
The Coating Distinctness of Image (DOI) meter is an optical instrument used for quantifying the imaging clarity of coating surfaces. It analyzes the reflection of standard patterns on the coating, measuring the ratio of specular reflection to diffuse reflection to obtain an objective DOI value.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.