Light Source Color Matching Cabinet

The light source color matching box simulates various lighting conditions by incorporating multiple standard light sources, such as D65 daylight and TL84 fluorescent lamps, allowing observers to compare color differences between samples and standards in a stable environment. It is used in industries such as coatings, inks, and textiles to ensure consistency and accuracy in color evaluation.
Selection
When selecting a light source for a color assessment cabinet, it is essential to consider whether the required light source types cover industry standards, such as D50 for printing and D65 for textiles. The cabinet size should accommodate the samples to be tested, and the interior walls should be neutral gray to avoid interference from reflections. Additionally, check the lifespan of the lamps and the ease of replacement, and ensure compliance with international standards such as ASTM D1729.

Terms

Standards

Instruments

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

With illumination adjustment function, support D65 Illuminant to meet CIE Class A Light spectrum matching, no need to warm up and no flicker, equipped with 45 degree observation station to achieve 45/0 observation conditions, suitable for large items Colorimetric.

$ 4237.00

Standard light source without preheating, can automatically switch and record the use of time, the use of composite engineering plastic baseplate to ensure ten years without yellowing, support Metamerism detection function.

$ 396.00

Using high color rendering index CRI = 98 D65 light source, equipped with 4 36W lamps and light source Timer, all-metal structure to ensure stable and uniform light, in line with ISO3664 international standards.

$ 1735.00

Configuration of 6 Standard light sources including D65 and UV Illuminant, equipped with 45 degree observation station to achieve 45/0 observation conditions, no need to warm up without flashing, high luminous efficiency Color evaluation fast and reliable.

$ 1171.00

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Articles

Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Reflectometer Selection: Light Source Geometric Conditions and Contrast Ratio Testing
This article primarily discusses that when selecting a reflectometer, the geometric conditions of the light source are crucial, as they directly affect the accuracy of the measurement results.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Differences between xenon arc lamps, carbon arc lamps, and UV lamps in automotive interior and exterior light aging tests
Xenon lamps, carbon arc lamps, and UV lamps are three commonly used light sources in the photodegradation testing of automotive interiors and exteriors. Xenon lamps can simulate the full spectrum of sunlight, and by adjusting filters, they can match different environmental conditions, making them suitable for comprehensive evaluation of material aging.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.