Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Measurement range 0-1500 μm, error +/- (3% H + 1) μm, can store 500 data and has a variety of statistical functions, suitable for a variety of Probe and Calibration methods.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.
Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.
Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.
Adopt magnetic thickness measurement method, measurement range 0-1250μm, error +/- 3%, with continuous and single measurement mode, can store 1560 measurement data, support a variety of calibrating methods.
Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.
Using magnetic principle, Coating thickness can be measured within 10 microns, Probe wear-resistant times more than 500,000 times, with single point, five point calibrate and Data storage function, suitable for inner hole or narrow position.
Measurement principle using magnetic method, thickness range 0-3000μm, error +/- 3%, with split Probe structure, support single and continuous Measurement mode, equipped with RS-232C interface.
Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.
Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250μm, error +/- 3%, with automatic zero-point proofreading, two-point Adjustment, support upper and lower limit overrun alarm and backlight display.
Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.