Haze and transmittance Tester

The haze and transmittance tester illuminates a sample with a light source, measures the total transmitted light and the proportion of scattered light deviating from the incident direction, and calculates haze and transmittance. It is used to evaluate the clarity and light transmission performance of transparent materials and is applied in quality testing of plastic films and glass products.
Selection
When selecting a haze transmittance tester, it is essential to confirm that the measurement standards comply with specifications such as ASTM D1003, check that the instrument's range covers 0-100% transmittance and 0-30% haze, verify the traceability certificate of the calibration plate, consider the adaptability of the sample fixture, and ensure that the operation interface meets daily testing requirements.

Terms

Standards

Instruments

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.

$ 11337.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.

$ 20729.00

Test without preheating, test time is only 2 seconds; LED Illuminant life up to ten years; can store 20,000 sets of data; support vertical and horizontal measurement methods.

$ 1364.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor to achieve 0.01 unit haze resolution; Equipped with dynamic measurement function, real-time monitoring of environment changes to ensure data Reliability; Open measurement area supports vertical horizontal test.

$ 7464.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy to achieve High Accuracy Transmittance and haze measurement, Repeatability is less than 0.05, Support a variety of observation Illuminant and dynamic temperature monitoring.

$ 7464.00

Compact and portable, with a resolution of 0.01, Repeatability ≤ 0.02, supports three measurement diameters and three Standard light sources, meeting a variety of Sample sizes and test standards.

$ 396.00

Compact and portable, supports three Standard light sources and dual light path design, measurement resolution up to 0.01, Repeatability ≤ 0.02, data cloud storage can be connected through the mobile phone Mini Program.

$ 557.00

Compact and easy to carry, resolution up to 0.01, Repeatability ≤ 0.02. Adopts dual light path design, supports three Standard light sources and multiple measurement calibers, and data can be stored in the cloud through the mobile phone Mini Program.

$ 719.00

Adopt LED Illuminant to achieve 0~ 100% measurement range, resolution up to 0.1, support single continuous measurement mode, lightweight structure only 100g, can be through USB/RS-232/Bluetooth multi-mode data transmission.

$ 380.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor, Measurement time of about 1.5 seconds, support dynamic measurement and a variety of observation Illuminant, ensure accurate and reliable data, adapt to different sample testing needs.

$ 14080.00

Articles

Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.