Double Magnetic Stirrer

The dual magnetic stirrer drives the rotation of the stir bars inside containers through the rotation of the base magnet, achieving synchronous stirring and mixing in two containers. It is used for scenarios such as solution stirring, reactant mixing, and temperature control in the laboratory.
Selection
When selecting, consider matching the heating power with the sample requirements, ensuring the stirring speed range covers experimental needs, the material's corrosion resistance is compatible with the solution properties, the dual-station size accommodates experimental containers, and the operation interface is simple and easy to control.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Double station synchronous operation, heating power 150W × 2, Temperature range RT +~ 100 ℃, using DC motor to ensure no noise and no vibration, fast IT single chip microcomputer to achieve accurate speed control.

$ 128.00

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

Double head design can process two samples simultaneously, stirring speed of 2400rpm, Temperature range from room temperature to 100 ℃, suitable for stable mixing and heating of small volume solutions.

$ 277.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Adopt double grinding head linear friction mode, load 570 +/- 20g adjustable, working plate Rotation speed 0~ 135rpm, magnetic chuck design makes sample loading and unloading convenient, the counter directly reads the number of sanding.

$ 696.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, digital display Rotation speed is clear and intuitive, suitable for large-capacity stirring needs.

$ 545.00

Max. stirring Capacity 1000mL, Speed range 0-1600rpm, using magnetic field drive technology implementation of non-contact stirring, suitable for a variety of low viscosity liquid mixing needs.

$ 107.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 1500rpm, equipped with strong magnetic steel to ensure strong stirring force and stable Rotation speed, Temperature range RT +~ 150 ℃, Heating power 360W adjustable, support mechanical timing 20~ 120min.

$ 212.00

The equipment provides 12-station simultaneous processing, stirring speed range of 0~ 2400rpm, using one-way Stir mode, working plate size is about 125 * 12cm, suitable for small volume sample precision stable Stir.

$ 372.00

Single chip digital control technology, with heating plate and liquid temperature double automatic temperature control function, temperature control accuracy +/- 1 ℃, Max.stirring Capacity 5L, support 0-250 minutes timing and 1500rpm Rotation speed adjustment.

$ 298.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Adopt abrasion-free magnetic coil technology, Speed range 60~ 2000rpm, support cycle swirl/spin and clockwise setting, IP65 waterproof rating, quieter and lighter operation.

$ 153.00

Rotation speed is stable with brushless DC motor, torque is 73.5mN · M, magnetic force is especially strong, suitable for large capacity stirring, Max. stirring Capacity 20L, Speed range 60~ 2000rpm.

$ 323.00

Articles

Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Analysis of the Influence of Temperature and Humidity on Paper Folding Endurance Testing
This article analyzes the impact of temperature and humidity on paper folding endurance testing. Paper folding endurance testing is typically conducted under standard temperature and humidity conditions, such as 23°C and 50% relative humidity.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.
Tensile testing machine for testing the bonding strength of wood plywood.
This article introduces the method for testing the bonding strength of wood plywood using a tensile testing machine. The test involves stretching plywood samples to measure the strength of the adhesive interface, in accordance with national standards such as GB/T 17657-2013.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.
How much does the sampling direction affect the accuracy of the short-span compression tester for measuring cardboard compressive strength?
The short-span compression tester is used to measure the edge crush resistance of cardboard, but the sampling direction significantly affects the results. The compressive performance of cardboard differs in the machine direction and the cross direction, with experimental data showing a strength difference of 20% to over 50% between the two.