Density Electronic Balance

The density electronic balance calculates the density of a sample by weighing the mass difference of the sample in air and liquid, combined with the density of the liquid. It is used for measuring the density of solids and liquids, and is applied in quality control within the chemical and materials industries.
Selection
When selecting, consider that the weighing range covers the sample weight, the accuracy meets the testing requirements, and it is equipped with density components and temperature compensation functions. Choose the appropriate basket or support based on the sample form to ensure easy instrument calibration.

Terms

Standards

Instruments

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 300g and readability up to 0.01g. Standard Density kit and RS232 interface facilitate data transmission.

$ 446.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and solid Density, volume and metal purity measurement are supported.

$ 716.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 120g readability 0.1mg, standard Density kit and various unit switching functions.

$ 887.00

Density direct reading function eliminates the calculation step, can measure solid and liquid density, accuracy of 0.01g, Repeatability +/- 0.01g, all aluminum base design enhances weighing Stability.

$ 415.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, supports liquid Density measurement and custom setting of Density upper and lower limits, and standard RS232 interface is convenient for data transmission.

$ 496.00

Density direct reading function eliminates calculation steps, can measure solid and liquid density, accuracy to three decimal places, equipped with display shield and all aluminum base, enhanced dust and Stability.

$ 680.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 220g readability 0.1mg, standard Density kit and RS232 interface support data export.

$ 932.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading response time is less than 3 seconds, supports multiple unit switching and external calibrating, and the standard Density kit is easy to install and operate.

$ 509.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading function response time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, standard RS232 interface supports data direct transmission.

$ 845.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, standard RS232 interface supports data direct transmission.

$ 457.00

High Accuracy Electromagnetic Force Sensor, Density Direct Reading Response Time Less Than 3 Seconds, Capacity 220g, readability 0.001g, Standard Density Weighing Kit and RS232 Interface.

$ 751.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeter customization are supported, and RS232 interface is standard for data transmission.

$ 935.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading response time is less than 3 seconds, standard Density kit is easy to install, supports a variety of weighing units and RS232 data output.

$ 1022.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Application of Solvent Rub Tester in the Coatings Industry
The solvent rub tester is a detection device used to test how many times a coating surface can withstand solvent rubbing without being damaged, thereby evaluating the curing quality, durability, and cross-linking density of the coating.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.