High-speed disperser for small-scale coatings.

The small high-speed paint disperser utilizes a high-speed rotating serrated dispersion disc to generate shear force, rapidly and uniformly mixing paint powder with liquid. It is used for the preparation and formulation debugging of small batches of paints and inks in laboratories, capable of performing operations such as dispersion, dissolution, and suspension.
Selection
When selecting, consider matching the material viscosity with the motor power. The material of the dispersion disc must be corrosion-resistant, and the speed range should cover the experimental requirements. Pay attention to the compatibility between the working capacity and the container. The mechanical structure should facilitate cleaning and maintenance, and operational stability should be verified through no-load testing.

Terms

Standards

Instruments

Speed range 0~ 20000rpm wide adjustable, equipped with high-speed series motor and stable silicon control system, integrated photoelectric speed measurement to ensure accurate reading, compact structure and convenient operation.

$ 351.00

Adopt thyristor high-speed adjustment system, photoelectric speed measurement electronic circuit to ensure reliable Rotation speed, homogenization knife Speed range of 22000rpm, Processing capacity 1000ml, easy to operate and intuitive reading.

$ 361.00

The equipment integrates stirring, dispersing, grinding functions, motor Power 750W, speed range 60~ 8000rpm, can handle materials with a viscosity of 100000mPa.s, through high-speed swirl/spin to generate strong shear force to achieve efficient Mixing & dispersing.

$ 675.00

Adopt dual-axis constant force lifting system, lifting Travel 400mm; Rotation speed up to 8000rpm, linear speed up to 41m/s; High-speed dispersion disc generates strong shear force to achieve uniform dispersion and suspension effect of materials.

$ 669.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, dispersion head generates swirl/spin tangential high line speed under high speed drive, through hydraulic shearing and high frequency mechanical effects to achieve efficient mixing, dispersion and homogenization.

$ 333.00

With a wide speed range of 0~ 10000rpm and 280mm lift Travel, using frequency conversion electromechanical operation quiet noise, support high-speed dispersion, stirring and grinding functions, suitable for 0~ 2L Processing capacity.

$ 772.00

The equipment uses a spring lift system, lift Travel 200mm, speed range of 60~ 8000rpm, can adapt to different experimental needs, through the digital PID technology implementation High Accuracy control, and provide dispersed impeller and sand grinding disc.

$ 801.00

The equipment uses an electronic constant force speed line, digital direct display Rotation speed, speed range of 100 to 8000rpm, maximum processing viscosity of 100000mPa.s, to adapt to different test needs, through high-speed shearing and high-frequency mechanical effects to achieve efficient mixing and dispersion.

$ 436.00

Rotation speed up to 12,000 rpm, driven by vertical single-phase series motor, Power 200W, compact size and low power consumption, can be split, crushed and blended to meet the requirements of aseptic operation.

$ 209.00

Adopt dual-axis constant force lifting system, lift Travel 200mm, speed range 60-8000rpm, digital direct display Rotation speed, equipped with dispersed impeller and sand grinding disc, adapt to different experimental needs.

$ 653.00

Using frequency conversion control to achieve a wide range of 60~ 8000rpm speed regulation, the maximum processing viscosity of 100000mPa.s, set dispersed ground stirring function in one, through high-speed swirl/spin to pRoduce a strong shear effect to improve the mixing efficiency.

$ 515.00

The axial flow fan is used to supply air and support stepless speed regulation of 0~ 3m/s, and the anemoMeter has a range of 0~ 10m/s, which is suitable for the determination of the initial drying anti-cracking performance of laminated architectural coatings.

$ 490.00

Set dispersion and Stir functions in one, the two processes of dispersion and homogenization are completed by one machine, with high efficiency, good mixing effect and easy cleaning. Speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, electric lifting mode is simple and convenient to operate.

$ 493.00

The maximum processing viscosity is 100000mPa.s, the speed range is 60~ 8000rpm, and the three functions of dispersion, grinding and stirring are integrated. Rotation speed and low noise operation are realized by frequency conversion control.

$ 528.00

With a speed of up to 30000rpm and a processing viscosity of 10000mPas, the claw-type high-shear structure and interchangeable stator and rotor provide triple safety protection and continuous 6-speed regulation, ensuring efficient dispersion and durability.

$ 1224.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.