Four Color Assessment Cabinet

The four-standard light source box is equipped with multiple standard light sources, which simulate lighting conditions such as daylight and store light to provide a stable observation environment. It is used in industries such as textiles and printing to compare colors under uniform lighting, reducing color difference judgment errors caused by variations in light sources.
Selection
When selecting, confirm the required standard light source type such as D65 or TL84, and check whether the illuminance is uniform and stable. Ensure the cabinet size is suitable for the samples to be tested. The inner walls should be neutral gray to avoid reflective interference and should have metamerism detection capability. Consider the lifespan of the lamps and the convenience of replacement. Determine the durability of the cabinet material based on the actual frequency of use.

Terms

Standards

Instruments

With four Illuminant automatic switching function, display the use time of each Illuminant, no need to warm up without flashing, Color temperature range covers 2700K to 6500K, low energy consumption without heating, support Metamerism detection.

$ 354.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

Four Illuminant configuration includes D65, TL84, F and UV, Illuminant automatically switches without preheating, supports Metamerism function, volume 710x405x570mm, weight 28Kg, low energy consumption and no heat generation.

$ 299.00

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Standard light sources covering 6500K to 2700K Color temperature range, support UV detection; no need to warm up and open immediately, low energy consumption without heating; Illuminant use time can be displayed, with 45 ° standard stand optional.

$ 315.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

With Metamerism function, no need to warm up without flashing, including seven kinds of Illuminant including D65 (6500K) and UV (365nm), automatically switch Illuminant and display the use time.

$ 477.00

Standard light source without preheating, can automatically switch and record the use of time, the use of composite engineering plastic baseplate to ensure ten years without yellowing, support Metamerism detection function.

$ 396.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

Imported aluminum surface reflector and uniform light cover, good light uniformity, CRI ≥ 95, Color temperature 6500K, can open the design for easy replacement of lamps, behind the hook and load-bearing steel chain for easy hanging.

$ 557.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

With three light sources including D65, TL84 and D50, high color strength index CRI = 98, the all-metal material is stable in structure, providing uniform lighting and accurate color evaluation, suitable for a variety of industry environments.

$ 1961.00

Articles

Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Principles, Differences, and Application Selection Guide for 4 Common Laboratory Coating Machines
This article will delve into the working principles, technical distinctions, and typical applications of four core laboratory coating devices in laboratory settings.