Viscosity Test Stirring Thermostatic Bath

The viscosity test stirring constant temperature bath maintains the sample at a constant temperature through its heating and stirring system, eliminating the influence of temperature on viscosity. It is used to ensure temperature stability during viscosity testing of fluids such as coatings and inks, guaranteeing data consistency.
Selection
When selecting, consider that the temperature range covers the sample testing requirements, the temperature control accuracy meets standard specifications, the stirring speed ensures sample uniformity, the tank material is corrosion-resistant, and the dimensions accommodate the sample containers.

Terms

Standards

Instruments

Driven by brushless DC motor, Max. stirring Capacity up to 10 liters, stirring speed range of 150-2000rpm, with super stirring force, suitable for high viscosity liquid stirring.

$ 227.00

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

Four-hole independent magnetic stirring can be stepless speed regulation and display Rotation speed, Temperature range 15~ 120 ℃, Temperature Fluctuation +/- 0.05 ℃, 4-sided Glass design is easy to observe sample changes.

$ 1492.00

With internal and external circulation thermostatic function, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support eight Rotation speed control, repRoducibility +/- 1%, suitable for accurate viscosity testing.

$ 1421.00

4-Sided Glass design is easy to observe sample changes, four-hole independent temperature control accuracy +/- 0.05 ℃, magnetic stirring can be stepless speed regulation, accelerate liquid temperature transfer, achieve rapid uniform heating.

$ 1944.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Adopt microcomputer PID temperature control, temperature control accuracy +/- 0.5 ℃, ensure temperature stability. Magnetic stirring output torque, keep Rotation speed constant, over-temperature sound and light alarm to protect sample safety.

$ 1016.00

The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.

$ 148.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Max. stirring Capacity 10L, stirring speed 100-2000rpm, stainless steel face, strong stirring force suitable for high viscosity liquid, Continuous Operating Mode.

$ 238.00

The four-blade structure makes the mixed medium flow radially up and down, forming strong turbulence and high shear force. The diaMeter of the slurry is 40mm, which is suitable for stirring medium and high viscosity liquids.

$ 96.00

The four-blade structure makes the mixed medium flow radially up and down, forming strong turbulence and high shear force. The diaMeter of the slurry is 120mm, which is suitable for stirring medium and high viscosity liquids.

$ 128.00

Driven by brushless DC motor, strong stirring force, Max. stirring Capacity 5L, temperature control accuracy +/- 1 ℃, suitable for thermostatic stirring occasions in various fields.

$ 249.00

With two-way stirring function, commutation time 5-30 seconds adjustable, Max. stirring Capacity up to 3000mL, Heating power 360W stepless adjustable, support mechanical timing 0-120 minutes.

$ 211.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.