Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
Support pH, conductivity and other 7 paraMeter measurement, accuracy of 0.001 level, with 3000 data storage and IP57 protection, Type-C charging interface for outdoor use.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Equipped with 3.5-inch TFT color screen and navigation operation, supports conductivity 0~ 2000.0mS/cm automatic segmented measurement, with ElectRode constant optional, manual automatic temperature compensation and 3000 groups of Data storage, using Type-C charging and IP57 protection design.
Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Measurement range 2~ 3000 μ S/cm, with good waterproof performance and stable conductivity measurement ability.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.
Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.
Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.