Patch Initial Tack Tester

The patch initial tack tester measures the initial adhesion force between the patch surface and the test object using the inclined plane rolling ball method or the probe penetration method. It is used to evaluate the immediate adhesion effect of patch products under slight pressure, and is suitable for quality control and production process monitoring of products such as medical patches and adhesive tapes.
Selection
When selecting, pay attention to the compatibility with testing standards, such as methods specified in pharmacopoeias. Consider the compatibility of sample dimensions with instrument fixtures, ensuring the pressure sensor range covers the common adhesive force range of patches. Prioritize models that automatically calculate adhesive force to minimize human error. Regularly verify instrument accuracy using standard weights.
Tilt angle

Terms

Standards

Instruments

Adopting the test principle of inclined rolling ball method, the tilt angle adjustment range is 0~ 40 °, equipped with 32 GCr15 bearing steel balls, and the shape tolerance accuracy exceeds GB/T308 level 40 to achieve accurate initial Tack evaluation.

$ 296.00

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

Adopting the principle of the inclined rolling ball method, the adhesion is measured by the short contact between the steel ball and the sample, the adjustment range of the tilt angle is 0-60 °, and the rolling ball of 1/32 to 1 inch is supported. The width of the test area is 80mm.

$ 338.00

Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.

$ 174.00

Using imported Sensor and motor, Measurement range 0~ 200N, accuracy less than +/- 1%, can store 20 sets of data and automatically print reports, support a variety of substrate replacement.

$ 3419.00

The axial flow fan is used to supply air and support stepless speed regulation of 0~ 3m/s, and the anemoMeter has a range of 0~ 10m/s, which is suitable for the determination of the initial drying anti-cracking performance of laminated architectural coatings.

$ 490.00

When the temperature reaches 90 ° C, the patch changes from white to black, with irreversible discoloration characteristics; the reflective display function is convenient for day and night inspection to detect temperature abnormalities, with a size of 25 * 21mm.

$ 81.00

Using irreversible discoloration technology, white turns black after overheating and displays numbers at the same time. Measuring temperature 80 ° C, diaMeter 2 cm circular patch design, suitable for indoor environment use.

$ 88.00

Six-station synchronous test, timing accuracy of 99 hours 59 minutes 59 seconds, using imported proximity switch and laser cross-cut test board to ensure accurate and reliable data, with automatic timing and anti-data loss function.

$ 812.00

Sensor and motor imported, Measurement range 0~ 100N, accuracy less than +/- 1%, Test speed 300mm/min, can record the maximum tension and failure mode.

$ 1853.00

70 ℃ rated temperature monitoring, irreversible discoloration characteristics ensure the accuracy of temperature recording, 40 * 40mm square patch design for easy installation and observation, reflective display function supports all-weather monitoring.

$ 81.00

Measurement range 0~ 500N, accuracy less than +/- 1%, can store 20 sets of results and print reports, humanized fixture supports a variety of substrates.

$ 3419.00

Measurement range 0~ 100N, accuracy less than +/- 1%, can store 20 sets of data and print reports, humanized fixture supports a variety of substrates.

$ 3419.00

Sensor and motor imported, Measurement range 0~ 300N, accuracy less than +/- 1%, can store 20 sets of data and automatically calculate the maximum, minimum, average, support a variety of substrate testing.

$ 3419.00

Using imported Sensor and motor, Measurement range 0~ 50N, accuracy less than +/- 1%, can store 20 test results and print reports, humanized fixture supports changing substrate.

$ 3419.00