Oscillation densitoMeter

Oscillation densimeters determine the density of liquids or slurries by measuring changes in the vibration frequency of the sample tube. The sample tube is electromagnetically driven to oscillate, and its frequency varies with the density of the sample. A sensor detects the frequency and converts it into a density value. This method is used for density monitoring and quality inspection in production processes across industries such as coatings and inks.
Selection
When selecting, consider that the measurement range should cover the sample density interval, and the precision should meet the inspection requirements. Pay attention to the influence of sample temperature and configure a temperature control unit. Choose an appropriate material for the measurement cell based on the corrosiveness of the sample. Verify the viscosity applicability range; special designs are required for high-viscosity samples. Ensure that the interface format is compatible with existing equipment.

Terms

Standards

Instruments

Set thermostatic foster and oscillation function in one, Temperature range 4-65 ℃, Oscillation Frequency 40-300rpm, microcomputer PID control to ensure that the temperature fluctuation is only +/- 0.2 ℃, 304 stainless steel liner easy to clean, support continuous operation.

$ 2068.00

Adopt horizontal press measurement and physical positioning observation window, density Repeatability ≤ 0.001D, chroma Repeatability dE * ab ≤ 0.03, provide nearly 30 kinds of Measurement parameters and more than 30 kinds of evaluation Illuminants, and support connection PC software and mobile end applications.

$ 3285.00

Rotation speed 2500rpm, can handle 2000ml volume sample, integrated magnetic stirring, vortex mixing and microplate oscillation multi-function.

$ 396.00

Using the rotary oscillation mode, Oscillation Frequency up to 3000 rpm, swing amplitude of 5mm, through smooth contact to achieve rapid mixing, speed can be adjusted with pressure, suitable for a variety of laboratory applications.

$ 133.00

With +/- 0.1 ℃ high temperature control accuracy and 0-200rpm Oscillation Frequency, using rotary oscillation and 8-hole design to ensure experimental Temperature uniformity and Sample Handling conformity.

$ 1122.00

Temperature control accuracy of +/- 0.1 ℃, Oscillation Frequency Range start to 320rpm, support reciprocating oscillation mode, spring bottle rack adapts to a variety of comparison tests, easy to operate, safe and smooth operation.

$ 1071.00

Temperature control accuracy +/- 1 ℃, Oscillation Frequency range 0~ 300rpm, using reciprocating oscillation mode, with reasonable structure, easy operation, high stability performance.

$ 548.00

Temperature Fluctuation +/- 1 ℃, Oscillation Frequency 30~ 150rpm, stainless steel liner anti-corrosion, support multi-stage programming control, heating drying test.

$ 1430.00

With vertical oscillation mode, Oscillation Frequency up to 280rpm, pendulum amplitude of 20mm, smooth operation and low noise, stepless speed regulation can be flexibly adjusted, stainless steel spring fixture is suitable for a variety of test bottles.

$ 393.00

Integrated mixing oscillation incubate three functions, temperature accuracy +/- 0.5 ℃, speed 200-1800rpm, metal module anti-pollution, support multi-point operation and timing operation.

$ 1437.00

Adopt horizontal oscillation mode, Frequency 0-240rpm continuously adjustable, stable work and low noise, equipped with 340 * 250mm tray to meet the needs of a variety of experimental containers.

$ 199.00

Temperature control accuracy of +/- 0.1 ℃, Temperature resolution of 0.1 ℃, with over-temperature alarm and 9999 minutes timing function, using stepless speed control motor to achieve low noise oscillation, to meet the needs of precision experiments.

$ 543.00

The horizontal and vertical combined oscillation mode is adopted, and any mode can be used alone. The stepless speed regulation range starts to 300 times/min, and the pendulum amplitude is 20mm, which has the characteristics of low noise and long life.

$ 490.00

With 0.1 ℃ temperature resolution and 20~ 300rpm Oscillation Frequency, it supports dual tray configuration and a variety of capacity options. The liner is made of 304 stainless steel to ensure stable operation and durability.

$ 3138.00

Temperature range 4~ 50 ℃ accuracy 0.1 ℃, Oscillation Frequency 20~ 300rpm adjustable, swing amplitude 26mm to ensure uniform mixing, 304 stainless steel liner corrosion resistance easy to clean.

$ 4037.00

Articles

Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Application of Solvent Rub Tester in the Coatings Industry
The solvent rub tester is a detection device used to test how many times a coating surface can withstand solvent rubbing without being damaged, thereby evaluating the curing quality, durability, and cross-linking density of the coating.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.