Heating Temperature Test Paper

Heating temperature indicator strips are based on the principle that thermosensitive materials undergo irreversible color changes at specific temperatures, and they are applied to the surface of objects to indicate whether the temperature has reached a preset value. They are used to monitor whether temperatures meet requirements during industrial heating processes, such as verifying temperatures in ovens, welding, or injection molding processes.
Selection
When selecting a temperature-indicating strip, it is essential to match the target temperature range, consider the surface characteristics of the substrate to determine the application method, pay attention to color change accuracy and response time, choose the type of protective coating based on environmental humidity, and verify that the certification standards meet industry requirements.

Terms

Standards

Instruments

Vacuum heating drying technology, Vacuum Level up to -0.098MPa, pumping 80-120 liters/min, drying time is only 4-6 minutes, with intelligent PID temperature control and over-temperature alarm function, easy and safe operation.

$ 2623.00

The maximum heating temperature is 300 ° C, the stirring speed is 0~ 1250rpm, the stirring time and thermostatic temperature can be set, and the external temperature sensor automatically controls the temperature to prevent the stirringRod from stalling.

$ 240.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

Maximum heating temperature 400 ° C, stirring speed 0~ 1250rpm, support external temperature sensor automatic thermostatic, key Rotation speed setting to prevent stirringRod stall, large screen LCD display temperature and stirring status.

$ 259.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Using high temperature non-alkali fiberglass insulation material sealing resistance wire, large heating area and heating fast, the highest temperature 380 ℃, support internal and external dual Sensor temperature measurement, no open flame design to avoid bumping Glass ware.

$ 170.00

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

Temperature range environment to 380 ℃, can work continuously, large heating area and rapid heating, effectively protect Glass ware.

$ 140.00

Double station synchronous operation, heating power 150W × 2, Temperature range RT +~ 100 ℃, using DC motor to ensure no noise and no vibration, fast IT single chip microcomputer to achieve accurate speed control.

$ 128.00

Heating power 800W, Temperature range RT +~ 999 ℃, no warping at high temperature, uniform working surface temperature, safe and simple operation.

$ 160.00

Using infrared radiation heating, fine grinding mirror drying surface, heating power 2.0KW, maximum temperature 180 ℃, drying size 600mm × 350mm, to ensure uniform drying and smooth surface.

$ 2462.00

Automatic dual-drive heating cabin door avoids human interference, 230 ° C limit heating temperature meets most samples, 0.001g High Accuracy weighing and 35cm heating cabin height improve test efficiency.

$ 2333.00

Adopting high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and no open flame design.

$ 143.00

Temperature range environment temperature to 380 ℃, can work continuously. The surface temperature of the heating element is up to 380 ℃, and the insulating layer is wOven with high temperature resistant fiberglass without alkali.

$ 117.00

Ceramic fiber insulation material, heating up to 1200 ℃ less than 30 minutes, temperature control accuracy +/- 1 ℃, low surface temperature, less heat pollution, with multi-step temperature control function.

$ 943.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.