Far Infrared Imager

Far-infrared imagers detect far-infrared radiation emitted from the surface of objects and convert it into visible thermal images. They are used for non-contact temperature measurement and thermal distribution analysis, with applications in equipment failure warning, building energy consumption detection, and medical diagnosis.

Instruments

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.

$ 507.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with stainless steel liner, rapid and uniform heating, suitable for drying a variety of samples.

$ 690.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control, fast low consumption, suitable for a variety of sample drying.

$ 756.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system, the studio is made of 304 stainless steel for fast and uniform heating.

$ 775.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system to achieve automatic thermostatic operation, the studio is made of 304 stainless steel, size 600 * 600 * 500mm.

$ 932.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast drying, low energy consumption and easy adjustment, suitable for a variety of Sample Handling.

$ 581.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, fast and low consumption, equipped with thermistor temperature control, the studio is made of 304 stainless steel, size 750 * 600 * 600mm, easy to adjust, suitable for drying treatment of various samples.

$ 840.00

Temperature range RT +~ 100 ℃, Temperature Fluctuation +/- 0.1%, using Far infrared heating and magnetic Stir technology, thermal equilibrating time is short and temperature uniformity is good, LED display is accurate and intuitive.

$ 522.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Granite structure ensures Stability, Measurement accuracy of (3 + L/200) μm, Repeatability of 0.002mm, Equipped with high resolution CCD and adjustable LED Illuminant to avoid workpiece deformation.

$ 9488.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.