Thermostatic Water Bath Unit

The constant temperature water bath heats the water tank through electric heating tubes and maintains a constant liquid temperature in conjunction with a temperature control system. It is used for constant temperature reactions of samples, reagent heating, and viscosity testing, commonly found in laboratory physical property analysis.
Selection
When selecting, consider the temperature range to cover experimental needs, temperature control accuracy to match sample requirements, tank size to fit the container dimensions, material corrosion resistance to suit the solvent type, and safety protection to include a dry-burning prevention function.

Terms

Standards

Instruments

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

Adopt electromagnetic pump circulation mode, Temperature range 5~ 80 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with water shortage protection function to prevent accidents, support a variety of interface connections.

$ 433.00

304 stainless steel one-time stretch forming liner, no water leakage; four-corner arc design to ensure temperature uniformity; temperature control accuracy of +/- 0.5 ℃, heating power 600W, to meet the long-term stable thermostatic needs.

$ 160.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing and over-temperature water cut-off alarm, to ensure the stability and safety of the experiment.

$ 285.00

Adopt stainless steel liner and microcomputer intelligent temperature control instrument, with 0.1 ℃ temperature resolution and +/- 0.5 ℃ Fluctuation, support timing and over-temperature water cut-off alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.

$ 188.00

It has the function of water shortage and air burning and independent temperature limiting system, temperature control accuracy +/- 0.3 ℃, adopts one-time stamping forming stainless steel liner, supports internal and external circulation and timing operation.

$ 459.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.