Constant Temperature Rotary Shaker

The constant temperature rotary shaker drives the platform to perform circular motion through a motor, combined with a temperature control system to maintain the set temperature. This ensures uniform mixing of samples at a constant temperature and is used in experimental processes such as dispersion testing of coatings and inks, as well as culture oscillation.
Selection
When selecting, consider whether the speed range and temperature control accuracy meet the sample requirements, and ensure that the platform size and fixtures match the container specifications. Pay attention to operational stability and temperature uniformity, and determine whether programming functions or anti-corrosion design are needed based on the application scenario.

Terms

Standards

Instruments

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Temperature range RT +~ 60 ℃, Oscillation Frequency 0~ 300rpm, intelligent integrated circuit to achieve no drift temperature control, rotary oscillation mode to ensure uniform mixing.

$ 1219.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, support double mode of rotary and reciprocating, Temperature range RT +~ 60 ℃, with 20mm swing amplitude, suitable for a variety of compounds to foster demand.

$ 932.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Using rotary oscillation mode, Oscillation Frequency 0~ 300rpm adjustable, temperature control accuracy +/- 1 ℃, with 5~ 120 minutes timing function, suitable for a variety of compounds thermostatic foster needs.

$ 548.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0~ 300rpm adjustable, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120 minutes flexible setting.

$ 740.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Integrated Incubator and Shaker functions, small footprint and large bottle capacity; Microcomputer PID control temperature and Oscillation Frequency, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner is easy to clean, supports multi-stage programming and UV sterilization to ensure safe and efficient operation.

$ 1773.00

Rotary oscillation with 0~ 300rpm Frequency range, temperature control accuracy of +/- 1 ℃, with 5~ 120 minutes timing function, suitable for a variety of compounds thermostatic foster needs.

$ 587.00

Temperature control accuracy of +/- 1 ℃, the speed range starts to 300rpm, with double oscillation mode of rotary and reciprocating, multi-functional spring bottle rack supports a variety of comparison experiments, safe and simple operation.

$ 601.00

Support 0~ 260rpm stepless speed regulation and rotary oscillation mode, equipped with stainless steel spring universal fixture, can be adapted to a variety of test bottles, smooth operation and low noise, to meet the needs of multi-sample mixing.

$ 519.00

Microcomputer Control Temperature Frequency Time, Large Screen LCD Display Three ParaMeters Simultaneously, Low Heat Dispersion Brushless DC Motor Wide Speed Constant Torque, Oscillation Frequency 40-250rpm amplitude 10mm, Adjustable Starting Torque and Automatic Protection Function.

$ 567.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Rotating Rubber Wheel Abrasion Tester for Determination of Coating Taber Abrasion Index
This article introduces the method for determining the Taber abrasion resistance index of coatings using a rotating rubber wheel abrasion tester.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.