Constant Temperature Liquid Bath

The constant temperature liquid bath maintains a stable temperature of the liquid medium in a closed system through a heater and a circulation pump. It is used for sample thermostatic treatment, viscosity testing, and reaction incubation, commonly applied in coating curing tests and ink fluidity detection.
Selection
When selecting, consider that the temperature range should cover the experimental requirements, with a fluctuation of less than ±0.5℃. Ensure the tank volume is suitable for the sample size, pay attention to corrosion-resistant materials and circulation flow rate, and check for safety protections and calibration functions.

Terms

Standards

Instruments

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature range -5~ 100 ℃, Temperature Fluctuation Accurate to +/- 0.05 ℃, equipped with circulating pump to support internal and external dual circulation mode, can flexibly meet the temperature control needs of in-tank and out-of-tank experiments.

$ 774.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, support double mode of rotary and reciprocating, Temperature range RT +~ 60 ℃, with 20mm swing amplitude, suitable for a variety of compounds to foster demand.

$ 932.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The coating machine applies a moisturizing lotion retention layer on the surface of the nonwoven fabric.
This article introduces the process of applying a moisturizing lotion retention layer on the surface of non-woven fabric using a film coating machine.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.