Electric water Bath heating Tank

The electric water bath heating tank heats the water medium through electric heating tubes and utilizes water to conduct heat, achieving uniform temperature control. It is used for constant temperature heating and dissolution reactions of laboratory samples, and is suitable for pre-treatment of materials in industries such as coatings and inks.
Selection
When selecting, consider the matching of heating power with tank capacity, and ensure temperature control accuracy meets experimental requirements. Stainless steel material offers corrosion resistance, and safety protection design should be noted. Choose the tank opening shape based on the sample container size, and ensure the observation window facilitates operation.

Terms

Standards

Instruments

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature range RT + 5~ 200 ℃, temperature fluctuation +/- 0.5 ℃, built-in circulating water pump can output thermostatic water flow, microcomputer intelligent temperature controller with timing and over-temperature alarm function.

$ 532.00

Temperature range RT + 2~ 99 ℃, Tank volume 20L, high performance CPU and Platinum Resistance Sensor for precise temperature control, stainless steel liner structure is durable.

$ 288.00

Temperature range RT + 2~ 99 ℃, Inner Chamber dimensions 300 * 150 * 115mm, stainless steel liner and high sensitivity Platinum Resistance Sensor, achieve precise temperature control.

$ 206.00

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

Using stainless steel liner and top cover, high performance CPU processing chip with high sensitivity Platinum Resistance Sensor to achieve accurate temperature control, Temperature range RT-100 ℃, Tank volume 10L, suitable for precision thermostatic experiments.

$ 225.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

The fully enclosed heating plate is designed without open flame, Heating power 3000W, heating up quickly and safely, and the studio stainless steel material has superior corrosion resistance.

$ 236.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing and over-temperature water cut-off alarm, to ensure the stability and safety of the experiment.

$ 285.00

Adopt stainless steel liner and microcomputer intelligent temperature control instrument, with 0.1 ℃ temperature resolution and +/- 0.5 ℃ Fluctuation, support timing and over-temperature water cut-off alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.

$ 188.00

Articles

Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.