Cardboard Moisture Analyzer

The cardboard moisture meter measures the moisture content of cardboard by detecting changes in resistance or capacitance. The probe contacts the surface of the cardboard, and moisture affects the electrical signal changes, which the instrument converts and displays as a moisture value. It is used to monitor material humidity during cardboard production and storage processes.
Selection
When selecting, focus on the measurement range covering the moisture content of common cardboard, and ensure the accuracy meets process requirements. Consider the probe type for compatibility with surface characteristics and ease of operation. Check for temperature compensation functions to guarantee environmental adaptability. Pay attention to the instrument's calibration cycle and maintenance costs.

Terms

Standards

Instruments

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Moisture is measured by thermogravimetry, equipped with 500W high-efficiency halogen ring lamp for uniform heating, Temperature range 40-180 ℃ controllable. 5-inch Touchscreen real-time display of moisture change Linear dispersion, support automatic shutdown and Data storage 100 groups, intuitive operation without supervision.

$ 420.00

Suitable for Coulometry moisture determination, containing 500mL KF-1A Reagent and 5 bottles of 5mL KF-1B Reagent, supporting a variety of Moisture Meters to meet the needs of laboratory moisture analysis.

$ 236.00

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Articles

Transverse Burst Strength Tester for the Evaluation of Impact Resistance of Corrugated Cardboard
This article explains how a lateral bursting strength tester is used to evaluate the impact resistance of corrugated cardboard. It measures the energy absorbed by the cardboard at the point of rupture using the pendulum impact principle, requiring the preparation of specimens according to standards and the control of environmental conditions during testing.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
The Taber stiffness tester is used for measuring the bending stiffness of paperboard.
The Taber stiffness tester is used to measure the bending stiffness of paperboard. Its principle involves applying a known bending moment to the specimen and measuring its resistance to deformation. Bending stiffness is a key performance indicator of paperboard, affecting its processing suitability and packaging functionality.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Key Operation Points of Carton Burst Strength Tester
The carton bursting strength tester is used to measure the maximum force that paperboard can withstand before rupturing under uniform pressure, which is important for packaging quality control. Before operation, ensure that the instrument is stable and the calibration is valid. The samples should be cut according to standards and conditioned under standard temperature and humidity conditions.
Selection Guide for Paperboard Puncture Strength Testers
This article introduces how to choose a cardboard puncture strength tester. The tester is used to measure the ability of cardboard to resist impact penetration, and multiple aspects should be considered during selection. First, check whether the instrument complies with relevant testing standards, such as national or international standards.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Correlation Analysis between Puncture Strength and Bursting Strength of Paperboard
This article analyzes the correlation between the puncture strength and burst strength of cardboard. The two properties respectively measure the ability of cardboard to resist dynamic impact and static pressure. Although their testing principles differ, both are closely related to factors such as the fiber structure and lamination process of the cardboard.
Selection Recommendations for Carton Compression Strength Testing Machines
When selecting a cardboard compression strength tester, the first step is to examine the core parameters, such as ensuring the force range covers the testing requirements with some margin, the accuracy is typically no less than ±1%, and the testing speed complies with standard specifications.