Liquid Constant Temperature Bath

The liquid constant temperature bath maintains a constant liquid temperature through heaters and circulation pumps, and is used in scenarios such as laboratory sample temperature control, reactor temperature regulation, and viscosity testing.
Selection
Consider temperature range and fluctuation, tank volume and opening size, material corrosion resistance, safety protection features, and circulation pump flow parameters when making a selection.

Terms

Standards

Instruments

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature range -5~ 100 ℃, Temperature Fluctuation Accurate to +/- 0.05 ℃, equipped with circulating pump to support internal and external dual circulation mode, can flexibly meet the temperature control needs of in-tank and out-of-tank experiments.

$ 774.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, support double mode of rotary and reciprocating, Temperature range RT +~ 60 ℃, with 20mm swing amplitude, suitable for a variety of compounds to foster demand.

$ 932.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude 20mm to ensure uniform mixing, timing function 0~ 120min to meet different experimental needs.

$ 740.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Using brushless DC motor to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 100 ℃, swing amplitude of 20mm, to ensure the stability and reliability of the experimental process.

$ 740.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.