Circulating Bath

The circulating bath drives a constant-temperature liquid to flow in a closed system through a pump, ensuring uniform heating of samples within the tank. It is used for maintaining constant temperatures in laboratory samples, controlling reactor temperatures, and conducting viscosity tests. It is commonly employed in chemical synthesis, material aging tests, and biological cultivation.
Selection
Select heating power and cooling configuration based on the experimental temperature range. Consider the compatibility of the bath size with the sample container. Pay attention to the temperature stability values and liquid compatibility. Check if the pump flow rate meets the heat transfer requirements. Note safety protection and ease of daily cleaning.

Terms

Standards

Instruments

Temperature Fluctuation control at +/- 0.05 ℃, Display resolution up to 0.1 ℃, equipped with circulating pump Flow rate 8L/min, support computer two-way communication and liquid level alarm to ensure stable and reliable experiment.

$ 1145.00

Temperature range -50~ 100 ℃, temperature resolution of 0.01 ℃, fully enclosed Compressor refrigeration and 304 stainless steel liner, equipped with 10L/min circulating pump and removable side panels for easy cleaning and maintenance.

$ 5931.00

Temperature control accuracy of +/- 0.05 ℃, resolution 0.1 ℃, equipped with 10L/min circulating pump and Pt100 temperature sensor, support computer communication and liquid level alarm function.

$ 2074.00

Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and magnetic stirring system to enhance experimental flexibility.

$ 1093.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface.

$ 3226.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level anti-dry burning and Compressor overload protection functions.

$ 6150.00

Temperature range -65~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity in the Tank.

$ 4801.00

Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 3155.00

Adopt non-heat centrifugal circulating pump to avoid self-heating affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control or magnetic stirring function to enhance application flexibility.

$ 1079.00

The double Compressor refrigeration system is adopted to ensure rapid cooling, the overall foaming and heat insulation of the Tank body reduces the cooling loss, the circulating pump Flow rate is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1816.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet the needs of complex experiments.

$ 12820.00

Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming Tank body to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 1293.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C and multiple Safety protection devices to ensure stable operation of the equipment.

$ 1668.00

Imported PT100 temperature sensor and double Compressor cascade refrigeration system, high refrigeration efficiency and low noise, Temperature Fluctuation +/- 0.05 ℃, Tank volume 30L, Circulating pump Flow rate 10L/min to ensure Temperature uniformity.

$ 3656.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 995.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.