Moisture Analyzer for Chemical Raw Materials

The chemical raw material moisture analyzer detects the moisture content of materials through heating or chemical reactions. The principle involves calculating the mass difference after water evaporates due to heating or using chemical reagents to react with water for measurement. Its purpose is to monitor the moisture content of raw materials, applied in quality control during the production processes of plastics, inks, and other materials.
Selection
When selecting, consider matching the heating temperature with the material properties to avoid decomposition. Choose halogen lamp or infrared heating methods based on accuracy requirements. Verify that the sample quantity is compatible with the instrument's capacity. Confirm compliance with industry testing standards and evaluate equipment maintenance costs and operational convenience.

Terms

Standards

Instruments

Using high frequency principle, Measurement range 0-60%, accuracy +/- 0.5%, Response Time 1 second, probe Sensor can penetrate deep into the material, support 20 kinds of material code selection.

$ 233.00

Using high frequency principle, measurement range 0-90%, resolution 0.1/0, Response Time 1 second, Sensor and host split design, Portable structure is suitable for on-site rapid detection.

$ 290.00

Using high frequency principle, Measurement range 0-99.9%, resolution 0.1/0, Response Time 1 second, portable design can be deeply measured inside the material, backlit LCD display is clear and low power consumption.

$ 233.00

Using high frequency principle to achieve 0~ 99.9% moisture measurement, probe Sensor can penetrate deep into the material, Response Time is less than 1 second, support on-site rapid detection and 9 sets of measurement codes.

$ 290.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Measurement range 0-99.9%, resolution 0.1%, Response Time 1 second, portable design supports rapid on-site detection, probe Sensor can penetrate deep into the material internal measurement.

$ 233.00

Adopting the principle of high-frequency electromagnetic wave induction, scanning depth 50mm, Response Time 1 second, support multi-gear measurement and plug-in rapid detection, small size for on-site use.

$ 233.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using constant current polarization detection technology, Measurement range 1μg-100mgH2O, accuracy of 0.1μgH2O, with automatic fault detection and dual-channel isolated power supply, effectively improve the test Stability and accuracy.

$ 5399.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Measurement range 0~ 60%, accuracy +/- 0.5%, Split Sensor design can go deep into the material internal measurement, Response Time is only 1 second, support 20 kinds of material code selection.

$ 290.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.