Digital Rotational Viscosity Meter

The digital rotational viscometer drives a rotor to rotate in the sample via a motor, measuring the torque generated by fluid resistance and converting it into viscosity data. It is used for detecting the viscosity of fluids such as paints and inks, guiding adjustments in production processes and quality control.

Instruments

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Equipped with four rotors, viscosity measurement range 20~ 100000mPa · s, fixed Rotation speed 6/12/30/60rpm, can display viscosity, Rotation speed, torque and maximum viscosity value, repRoducibility +/- 1% F.S.

$ 420.00

Viscosity measurement range 1~ 2000000mPa · s, repRoducibility +/- 0.5% F. S, sample volume only 25~ 30mL, Rotation speed control to meet different viscosity measurement needs.

$ 712.00

Measurement accuracy of +/- 1% F. S, repRoducibility of +/- 0.5% F. S, support continuously variable speed control Rotation speed 1~ 60rpm, real-time display of rotor measurable maximum viscosity value, easy to operate.

$ 943.00

Range 20~ 600000mPa · s, repRoducibility +/- 0.5% F. S, LCD screen can display viscosity, shear rate, Rotation speed and other Multi-ParaMeters, support stepless speed control and data printing output.

$ 1037.00

Equipped with an ultra-low viscosity adapter, the viscosity test is as low as 1cp, the sample volume is only 25~ 30mL, repRoducibility +/- 0.5% F. S, Measurement +/- 1% F. S, support stepless speed control.

$ 1059.00

Range 20~ 2,000,000 mPa · s, repRoducibility +/- 0.5% F. S, LCD display viscosity, Rotation speed, temperature and torque, easy operation and high accuracy.

$ 595.00

With thermal printer can output test data, viscosity range of 20~ 2000000mPa · s, Measurement accuracy +/- 5% F. S, repRoducibility +/- 1% F. S, support multi Rotation speed and rotor selection.

$ 630.00

Measurement accuracy of +/- 2% F.S, repRoducibility +/- 0.5% F.S, viscosity range covering 1~ 600000mPa · s, with screen direct display viscosity, speed, torque and alarm function.

$ 835.00

Viscosity range 6~ 80000000mPa · s, repRoducibility +/- 0.5% F. S, support continuously variable speed and LCD multi-ParaMeter display, sample volume only 25~ 30mL.

$ 1468.00

Viscosity measurement range of 160~ 80000000mPa · s, repRoducibility +/- 0.5% F. S, equipped with thermal printer can print key data such as temperature, Rotation speed, viscosity value and percentile torque in real time.

$ 1445.00

The LCD screen visually displays viscosity, Rotation speed, percentiMeter torque and rotor information, with a range of 20~ 2000000 mPa · s, repRoducibility +/- 1% F. S, and supports eight Rotor speed switches.

$ 536.00

Measurement accuracy +/- 1% F.S, repRoducibility +/- 0.5% F.S, support 0.3~ 60rpm multi-gear Rotation speed and RTD temperature sensor, can display the maximum viscosity value, suitable for accurate viscosity detection.

$ 614.00

Dial display, viscosity measurement range of 10~ 100000mPa · s, accuracy +/- 5% F. S, equipped with four rotors and four Rotation speed, suitable for a variety of fluid viscosity detection, easy to operate.

$ 346.00

Viscosity measurement range 160~ 80000000mPa · s, repRoducibility +/- 0.5% F. S, support continuously variable speed and a small amount of sample adaptation, only 10~ 20mL sample volume, easy to disassemble and clean.

$ 1732.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.
Rotational viscometer measures the viscosity of paint at low shear rates.
This article introduces the method and significance of measuring the viscosity of colored paint at low shear rates using a rotational viscometer.
Standard Method for Measuring the Melt Viscosity of Hot Melt Adhesives with a Rotational Viscometer
This article introduces the standard method for measuring the molten viscosity of hot-melt adhesives using a rotational viscometer. During the measurement, the hot-melt adhesive sample must be fully melted and degassed, placed into a measuring cup, and then measured with the rotational viscometer at a set temperature.
The cone and plate viscometer measures the rheological properties of a small amount of ink sample.
A cone-plate viscometer measures torque through rotation between the cone and plate, enabling the analysis of rheological properties with small ink samples. It is suitable for small-volume measurements, reducing interference from solvent evaporation.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.