Nitrogen Circulation Drying Oven

The nitrogen circulation drying oven operates by injecting inert nitrogen to displace the air inside the chamber. It utilizes a circulation fan to ensure uniform flow of hot nitrogen, enabling low-temperature drying of samples under oxygen-free conditions. This method is designed to prevent material oxidation and accelerate solvent evaporation, making it suitable for anti-oxidation treatment of electronic components and chemical raw materials.
Selection
Determine the temperature range and control accuracy based on material characteristics; select the inner chamber size according to sample volume; pay attention to nitrogen replacement rate and sealing performance; ensure uniform airflow with the circulation fan; consider explosion-proof design for scenarios involving organic solvents; reserve gas inlet interfaces to match existing nitrogen sources.

Terms

Standards

Instruments

Adopt hot air circulation system to ensure Temperature uniformity, Temperature Fluctuation +/- 1 ℃, volume 30L, with over temperature deviation protection and timing function, can adjust the air inlet and exhaust volume.

$ 453.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Temperature range RT + 10~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, hot air circulation system to ensure uniform temperature in the studio, optional RS485 interface to record temperature and humidity paraMeters.

$ 483.00

Temperature range RT + 10~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, using hot air circulation system to ensure uniform temperature in the studio, with independent temperature limit alarm and RS485 interface optional function.

$ 3170.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.5 ℃, hot air circulation system to ensure uniform temperature, with timing function and independent temperature limit alarm, support RS485 interface to record data.

$ 419.00

Adopt double circulation air duct system and stainless steel heating pipe, Temperature control accuracy up to +/- 1 ℃, Temperature resolution 0.1 ℃. Studio shelf adjustable, insulation layer thickness over 70mm, effectively reduce heat loss and improve Temperature uniformity.

$ 457.00

Temperature uniformity is improved by fan speed control, air duct circulation system automatically discharges water vapor, temperature control accuracy +/- 1 ℃, equipped with independent temperature limit alarm to ensure experimental safety.

$ 394.00

Temperature range RT + 10~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃. Stainless steel liner structure is durable, hot air circulation system ensures uniform temperature in the studio, supports timing function and temperature limit alarm protection.

$ 1739.00

Temperature range up to 500 ℃ and Fluctuation only +/- 1 ℃, equipped with hot air circulation system to ensure Temperature uniformity, support independent temperature limit alarm and RS485 Communication interface to meet the precise temperature control requirements in high temperature environment.

$ 1637.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.

$ 761.00

50L studio volume, Temperature uniformity is excellent, equipped with air duct circulation system to automatically discharge water vapor, temperature control accuracy +/- 1 ℃, support 1-9999 minutes timing function.

$ 407.00

Temperature range up to 500 ℃ and fluctuation only +/- 1 ℃, equipped with hot air circulation system to ensure Temperature uniformity, support 1-9999 minutes timing function, optional temperature recording and over-temperature protection device.

$ 2048.00

Adopt double circulation air duct system and stainless steel heating pipe, Temperature uniformity up to +/- 1 ℃, temperature control accuracy 0.1 ℃. Studio shelf adjustable, sealing structure resistant to high temperature aging, insulation layer thickness over 70mm to reduce heat loss.

$ 659.00

Using forced warm air circulation to ensure uniform temperature, Temperature resolution of 0.1 ℃, equipped with microcomputer LCD controller temperature control is accurate, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 457.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.