Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.
Measurement principle using Conductivity Detector method, Measurement range 8~ 40%, accuracy +/- 0.5%, with automatic compensation function of Temperature and Humidity, Response Time is only 1 second, Portable design weight about 203 grams, suitable for on-site rapid detection.
Conductivity Detector Measurement principle, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time only 1 second, with temperature and humidity compensation technology, probe Sensor can be deeply measured inside the material, support multi-gear design and Interface customization.
Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.
Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.
High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.
Temperature control accuracy +/- 1 ℃, rapid heating and over-temperature automatic interrupt function, adjustable fan Rotation speed and timing control, easy to clean the box.
Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.
Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.
Temperature control accuracy +/- 1 ℃, rapid heating using forced convection design. With over-temperature automatic interruption function, the shelf can be moved to facilitate cleaning in the box, ensuring safe and convenient operation.
Adopt high temperature dry heat technology, Temperature range RT + 10~ 250 ℃, Input Power 1550W, with High Accuracy Microcomputer LCD display, automatic over-temperature protection and forced convection design, shorten disinfection time.
Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and timing function, mirror stainless steel liner is easy to clean.
Temperature control accuracy of +/- 1 ℃, rapid heating and forced convection mode, equipped with over-temperature automatic interrupt function to ensure safe operation, studio volume of 50L easy to handle all kinds of items.
Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.