High-pressure Steam Sterilizer

An autoclave achieves sterilization by generating high-temperature saturated steam at 121℃ within a sealed chamber. The latent heat of the steam penetrates microbial cell walls, causing protein coagulation and denaturation. It is used for sterilizing heat-resistant items such as laboratory culture media and surgical instruments.
Selection
When selecting, consider that the inner tank material must be corrosion-resistant, the capacity should match the processing volume, safety devices should include a pressure gauge and a pressure relief valve, the heating method affects the heating speed, it is necessary to verify that the power specifications match the site, and pay attention to the impact of the cavity structure on steam circulation.

Terms

Standards

Instruments

Irreversible discoloration records the highest temperature, accuracy +/- 1 ° C to +/- 4 ° C, four-speed temperature monitoring range 104-121 ° C, oil-resistant, water-resistant and steam-resistant, instant Response without power supply.

$ 93.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.

$ 562.00

The line pressure range is 0.33~ 80N/mm, and the width of the pressing roller is 300mm, which can complete ordinary pressing, high-pressure pressing, smooth pressing and calendering experiments, and support a variety of blanket pressing tests.

$ 5399.00

Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.

$ 611.00

Adopting the principle of irreversible discoloration, the accuracy is +/- 1 ° C below 100 ° C, with 6 temperature grids from 65 ° C to 93 ° C, oil, water and steam resistance to ensure stable operation in harsh environments.

$ 93.00

Using high elasticity standard rubber and denim for extrusion test, extrusion pressure 10-120kgf adjustable, Test speed 5-30 times/minute, to meet the requirements of YD/1539-2006 standard.

$ 1079.00

Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.

$ 482.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.

$ 1066.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.

$ 749.00

Manual pressure control pressure holding operation is simple, electronic pressure holding device reduces mechanical abrasion, pressure range 0~ -90kPa, accuracy +/- 0.1kPa, Organic Glass sealing barrel wall thickness 15mm to enhance compressive strength.

$ 887.00

Adopt 24-bit High Accuracy AD converter and stable pressure sensor, Measurement range 50~ 1400kPa, with full scale alarm and 3-speed limit protection function, support a variety of Unit switches and thermal printouts.

$ 1501.00

Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.

$ 1098.00