Cyclic Constant Temperature and Humidity Test Chamber

The circulating constant temperature and humidity test chamber controls the temperature and humidity inside the chamber through compressors and humidifiers to simulate the weather resistance of products in different environments. It is used to detect the performance changes of materials under cyclic variations in temperature and humidity and is commonly employed for environmental adaptability testing of electronic components and coating products.
Selection
When selecting, consider that the temperature and humidity range must cover the test standards, with fluctuations controlled within ±0.5℃. The chamber volume should be determined based on the specimen size, and the stainless steel interior ensures corrosion resistance. Confirm that the unit has program editing functionality, and the compressor must meet the temperature change rate requirements. Pay attention to the anti-condensation design of the observation window and the configuration of standard test ports.

Terms

Standards

Instruments

Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.

$ 5307.00

Temperature range -60~ 130 ℃, humidity control 30~ 95% RH, non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 7377.00

Temperature range -60~ 150 ℃, Humidity control 30~ 95% R.H., non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 6588.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% R. H, using programmable multi-stage control and independent temperature limit alarm system, equipped with test holes and can be pulled out of the water Tank for easy operation.

$ 9843.00

Temperature range -40~ 150 ℃, humidity control 30~ 95% R.H., non-fluorine environmental protection refrigerant and imported Compressor, with independent temperature limit alarm system, support multi-stage programmable control.

$ 16459.00

Temperature range -40~ 150 ℃, Humidity control 30~ 95% R. H, Temperature Uniformity +/- 2 ℃. Using fluorine-free environmental protection refrigerant and imported Compressor, support multi-stage programming and data processing, with independent temperature limit alarm and a variety of Safety protection functions.

$ 5307.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Temperature range -40~ 150 ℃, Humidity range 30~ 95% RH; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and multiple Safety protection functions.

$ 7574.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% RH, equipped with imported Compressor and programmable Touchscreen, support multi-stage program control and real-time data recording, with independent temperature limit alarm and multiple Safety protection functions.

$ 7969.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Adopt equilibrating Conditioning Control system, Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, with multi-stage intelligent output and energy saving function, special air circulation design to ensure uniform temperature, built-in a variety of protection systems to ensure safe operation.

$ 3531.00

Temperature range -60~ 150 ℃, humidity control 30~ 95% R. H; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control function, support data export and remote monitoring, to ensure the accuracy and stability of the test process.

$ 13796.00

Adopt equilibrating Conditioning Control system, with multi-stage intelligent output to ensure stable Humidity. Temperature range -60~ 150 ℃, Humidity Control Range 20~ 98% R.H., with energy saving function and comprehensive protection system to ensure long-term accurate operation.

$ 6330.00

Adopt equilibrating Conditioning Control system, Temperature and Humidity control range -20~ 150 ℃ and 20~ 98% R.H., with multi-stage heating and energy saving functions to ensure long-term accurate operation.

$ 5039.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.