Portable Meat Moisture Tester

The portable meat moisture meter utilizes near-infrared spectroscopy technology to rapidly determine moisture content by contacting the meat sample with a probe. It is used in meat processing, storage, and market supervision to monitor product quality and prevent excessive moisture levels.
Selection
Focus on measurement accuracy and repeatability when selecting, ensuring the probe material complies with food contact standards. Choose an appropriate spectral range based on the type of meat, and verify the instrument's calibration certificate. Consider the operating environment's temperature and humidity range, and confirm that the battery life meets on-site usage requirements.

Terms

Standards

Instruments

Imported chips ensure stable performance, 1 second Fast Response to complete the detection, measurement range 10-85%, resolution of 0.1%, suitable for all kinds of fresh meat moisture determination.

$ 225.00

Using high frequency principle, the measurement range is 0-80%, the accuracy is 0.1/0, and the Response Time is 1 second. The probe type Sensor can penetrate deep into the material. The portable design weighs about 200 grams, which is suitable for on-site rapid detection.

$ 235.00

With +/- 0.05pH accuracy and open reference connection ElectRode, removable casing design for easy maintenance, battery life up to 1000 hours, suitable for use in harsh environments.

$ 299.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 0-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, and the portable design weight is about 203 grams, which is suitable for on-site rapid detection.

$ 144.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Conductivity Detector measurement principle, measurement range 0~ 84%, accuracy +/- 0.5%, Response Time 1 second, with temperature and humidity compensation technology, portable design weight only 265 grams, suitable for on-site rapid detection.

$ 160.00

Using high frequency principle, Measurement range 0-99.9%, resolution 0.1/0, Response Time 1 second, portable design can be deeply measured inside the material, backlit LCD display is clear and low power consumption.

$ 233.00

Temperature and humidity compensation technology to ensure accurate and stable measurement, Measurement range 0-84%, resolution 0.1%, Response Time less than 1 second, with MAX Maximum hold and automatic shutdown function, support a variety of data transmission interface customization.

$ 160.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, the portable and lightweight is only 203 grams, suitable for on-site rapid detection.

$ 138.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.