Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
Measurement range 20~ 90A, with MAX Maximum latch, under-voltage alarm and male/imperial unit conversion function, support USB and Bluetooth data output.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
Measurement range is 0~ 100HA, resolution up to 0.1HA, measurement error ≤ +/- 1HA (20-90HA), Ambient Temperature 0~ 40 ℃, Dimension 173 * 56 * 42mm, weight 233g, support RS232 communication cable.
Measurement range greater than 90B and less than 20D, with MAX Maximum latch, automatic shutdown and USB/Bluetooth data output functions, the error does not exceed 1H.
Portable design integrates measurement and data processing. Measurement range 0~ 100HA, error ≤ +/- 1HA, support peak hold, automatic timing and data communication functions.
Hardness measurement 0-100HD range, accuracy +/- 1HD, with automatic filtrate abnormal reading function, support 1000 sets of Data storage and real-time drawing, acid and waterproof design for industrial environment.
Measurement range greater than 90A, resolution up to 0.1H, with MAX Maximum latch and automatic shutdown function, support USB and Bluetooth data output, to meet a variety of hardness of materials testing needs.
Measurement range 0~ 100HA, resolution 0.1HA, can be connected to a computer for data transmission, with the test bench to achieve High Accuracy measurement, with automatic shutdown and undervoltage alarm function.
Measurement range > 90B < 20D, support male/imperial unit conversion, with average calculation and MAX Maximum latch function, can output data in various ways through USB/RS-232/Bluetooth.
Resolution 0.1H, Accuracy ≤ 1H, Measurement range 10~ 90 HA/HD; Integrated design is lightweight, supports male/imperial conversion, average calculation and a variety of data output methods.
Adopt R1.2 hemispherical pressure needle, Accuracy ≤ +/- 1H, support multi-unit measurement and automatic shutdown, suitable for soft rubber, thermal plasticity plastic and other materials, Operating temperature 0~ 50 ℃.
Measurement range 0~ 100HA, accuracy +/- 1HA, automatic filtrate invalid readings, solvent resistance, acid resistance, waterproof and dustproof, interchangeable platform to connect a variety of Probes, support USB data transmission.