With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with independent temperature controller, hot air circulation system consists of low noise fan and air duct, indoor shelf height and quantity can be adjusted.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with hot air circulation system and double-decked tempered Glass observation window, the height and number of shelves in the studio can be adjusted, which is convenient for accessing samples of different specifications.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, hot air circulation system consists of low noise fan and air duct, the height and number of shelves in the studio can be adjusted, double-decked tempered Glass observation window is convenient for observing samples.
Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%, equipped with hot air circulation system and double-decked tempered Glass observation window, adjustable shelf height and quantity, easy access to different specifications of samples.
Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%. The hot air circulation system ensures uniform temperature, double-decked tempered Glass observation window for real-time observation, shelf height and quantity can be adjusted to suit different samples.
Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with hot air circulation system and double-decked tempered Glass observation window, adjustable number of studio shelves height, support independent temperature control.
Temperature range RT + 5~ 300 ℃, Temperature Accuracy +/- 1 ℃, equipped with hot air circulation system and independent temperature controller, adjustable height of studio shelf, double-decked tempered Glass observation window for easy observation.
With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Adopt low noise fan and air duct to form hot air circulation system, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%, Inner Chamber dimensions 1000 × 800 × 800mm, shelf height and quantity can be adjusted, equipped with double-decked tempered Glass observation window.
Adopt hot air circulation system to ensure uniform temperature, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%; Inner Chamber dimensions 1000 * 1000 * 1000mm, shelf height and quantity adjustable, easy to access different specifications of samples.