Vacuum wear testing machine

The vacuum wear testing machine simulates wear behavior under real working conditions by reciprocally scraping the surface of materials with a friction pair in a sealed negative pressure environment. It is used to test the wear resistance of coatings, thin films, and other materials, commonly applied in fields such as ink adhesion and scratch resistance testing of packaging materials.
Selection
When selecting, it is necessary to match the thickness and hardness range of the test material, confirm that the friction head type is consistent with the actual wear form. Pay attention to the control accuracy of vacuum degree and the range of speed adjustment, and verify whether the sample clamping method is adaptable to different shapes. Consider the real-time recording capability of the data acquisition system to ensure compliance with relevant industry standards and specifications.

Terms

Standards

Instruments

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

The built-in vacuum pump realizes 0~ -80kPa Vacuum Level, the fully transparent vacuum Chamber can hold 12 samples, the program control supports 80 sets of paraMeter storage, and the vacuum cycle operation is automatically completed.

$ 4108.00

Vacuum chuck area of 300 * 400mm, equipped with 150W vacuum pump, aperture 0.8mm to ensure uniform adsorption, improve Spreader accuracy and Stability.

$ 638.00

The effective volume utilization rate of rectangular vacuum Chamber is high, each layer can be independently heated and vacuumed to inject nitrogen without interfering with each other, the temperature control accuracy is +/- 1 ℃, the Vacuum Level is 133Pa, and the double-decked tempered Glass door is easy to observe.

$ 7880.00

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level 133Pa ensures efficient handling, double-decked tempered Glass doors are easy to observe, and over-temperature protection enhances safety.

$ 4222.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

1Mm Vacuum aperture diameter and 18mm hole spacing design, equipped with 176 adsorption holes to ensure that the substrate is flat and fixed, with 150W vacuum pump to achieve stable adsorption effect.

$ 654.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures stoving conformity.

$ 2052.00

Double-decked independent heating and vacuuming do not interfere with each other, Vacuum Level up to 133Pa, rectangular vacuum Chamber improves space utilization, resilience silicone rubber door seal ensures high vacuum, over-temperature protection improves safety.

$ 4813.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

With two test stations, the load range is 50~ 1000g, and three typical wear resistance tests of alcohol, eraser and pencil can be carried out, which is suitable for wear resistance evaluation of various coatings and materials.

$ 572.00

The rectangular vacuum Chamber is used to improve the space utilization rate, each layer can be independently heated and vacuumed without interfering with each other, the temperature control accuracy can reach +/- 1 ℃ and the Vacuum Level can reach 133Pa, equipped with double-decked tempered Glass door for easy observation.

$ 5997.00

Rectangle vacuum Chamber improves space utilization, stainless steel studio is durable and easy to clean, double-decked tempered Glass door is easy to observe, Vacuum Level 133Pa, temperature control accuracy +/- 1 ℃, optional program control to ensure stoving conformity.

$ 16559.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures the stoving conformity.

$ 3294.00

Articles

Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Selection of Wear Testing Machine: Types of Abrasion Wheels and Load Setting Methods
The test results of the wear testing machine primarily depend on the type of grinding wheel and the load setting. Grinding wheels include rubber wheels, abrasive wheels, wire wheels, and fiber wheels, among others. The selection should be matched based on the material characteristics and the actual wear scenario.
Vacuum adsorption coating of perovskite precursors on flexible substrates.
This article introduces the process of vacuum adsorption coating for perovskite precursors on flexible substrates.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.