Electrically Heated Stirring Machine

The electric heating stirrer uses resistance heating and a motor-driven stirring rod to achieve material heating and mixing within a container. It is used for sample dissolution, reaction acceleration, and temperature control in laboratories, commonly employed in sample pretreatment processes in fields such as chemical engineering and food testing.
Selection
When selecting, consider whether the heating temperature range and stirring speed match the material properties, check the corrosion resistance of the materials, confirm the temperature control accuracy and stirring stability, verify the container capacity against experimental requirements, and inspect safety protection features such as overheat power cutoff.

Terms

Standards

Instruments

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

Driven by brushless DC motor, Max. stirring Capacity up to 10 liters, stirring speed range of 150-2000rpm, with super stirring force, suitable for high viscosity liquid stirring.

$ 227.00

Max.stirring Capacity 5L, stirring speed 0~ 2000rpm, using strong magnetic drive, suitable for medium capacity stirring, smooth and continuous operation.

$ 170.00

Max. stirring Capacity 10L, stirring speed 100-2000rpm, stainless steel face, strong stirring force suitable for high viscosity liquid, Continuous Operating Mode.

$ 238.00

Maximum stirring capacity 2 liters, Speed range 100 to 2000 rpm, Compact structure suitable for small capacity stirring, Continuous Operating Mode to ensure stable operation.

$ 141.00

Rotation speed is stable, Max. stirring Capacity 5L, stirring speed 60~ 2000rpm, strong magnetic steel stirring force, corrosion resistant engineering plastic shell.

$ 186.00

Brushless DC motor with strong magnet, strong stirring force; Maximum stirring capacity of 3 liters, Speed range up to 1500 rpm; Corrosion resistant shell and stainless steel face to ensure long-term stable operation.

$ 162.00

Four-hole independent magnetic stirring can be stepless speed regulation and display Rotation speed, Temperature range 15~ 120 ℃, Temperature Fluctuation +/- 0.05 ℃, 4-sided Glass design is easy to observe sample changes.

$ 1492.00

Maximum heating temperature 400 ° C, stirring speed 0~ 1250rpm, support external temperature sensor automatic thermostatic, key Rotation speed setting to prevent stirringRod stall, large screen LCD display temperature and stirring status.

$ 259.00

Rotation speed is smooth and not affected by Power supply frequency, torque is 73.5mN · M, magnetic force is particularly strong, suitable for large capacity stirring, Max.stirring Capacity 20L, speed range 60-2000rpm.

$ 311.00

Driven by brushless DC motor, Rotation speed is stable and rotation distance is 73.5mN · M, magnetic force is particularly strong, suitable for large capacity stirring, Max. stirring Capacity 20L, Speed range 60~ 2000rpm.

$ 319.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

With magnetic stirring function, the maximum stirring capacity of 2000ml, Speed range 200-2500rpm, vibration range 4.5mm, support point and continuous operation mode switching.

$ 359.00

4-Sided Glass design is easy to observe sample changes, four-hole independent temperature control accuracy +/- 0.05 ℃, magnetic stirring can be stepless speed regulation, accelerate liquid temperature transfer, achieve rapid uniform heating.

$ 1944.00

Brushless DC motor to achieve 100-2000rpm smooth stirring, double heating control loop to ensure temperature stability, aluminum die-casting ceramic coating plate with abrasion resistance and corrosion resistance, Max. stirring Capacity up to 20L.

$ 577.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.