Gel Time Tester

The gelation time tester determines the transition time of resins or coatings from liquid to solid by heating the sample and monitoring viscosity changes. It is used to control the curing characteristics of materials during the production process and is commonly employed in quality testing for paints, inks, and adhesives.
Selection
When selecting, consider matching the sample type with the heating method. Temperature control accuracy must meet standard requirements, and the operation interface should be simple and readable. Balance test repeatability and maintenance costs, while ensuring the equipment dimensions fit the laboratory space.

Terms

Standards

Instruments

Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.

$ 509.00

Aluminum alloy working platform and long life heating tube, Temperature range RT +~ 550 ℃, temperature error +/- 1 ℃, equipped with PID intelligent temperature Control system, can be customized heating Platform size according to demand.

$ 685.00

Using copper plate working platform and long life heating tube, PID intelligent temperature control to achieve +/- 1 ℃ accuracy, Temperature range RT + 10~ 300 ℃, with automatic thermostatic function, easy to operate.

$ 1009.00

The 10x30mm standard size design ensures a perfect match with the SH1117 Tester, providing accurate gel strength measurement results.

$ 694.00

Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.

$ 115.00

Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.

$ 96.00

Frequency adjustable continuously, stable operation and low noise, the device is suitable for gel treatment, molecular hybridization and X-ray film Development, etc.

$ 267.00

Working Frequency 0-240rpm continuously adjustable, equipped with 340 * 250mm tray, support swing oscillation mode, low running noise and stable performance, suitable for gel treatment and molecular hybridization and other experimental scenarios.

$ 180.00

Using plastic shell with 1 Meter BNC interface cable, specification is Φ 12mm × 120mm, built-in 3mol KCl gel reference solution without maintenance, Measurement range 0-14pH and 0-60 ℃, suitable for a variety of detection scenarios, providing stable and accurate acid alkalinity measurement.

$ 88.00

Using 200g weight and 1cm ² bottom area design, in line with GB/T 1728 standard, through the filter paper test method to accurately determine the film surface drying and practical drying time, easy to operate, reliable results.

$ 114.00

Glass sensitive film full sensing liquid pH, gel KCL reference solution to ensure long-term use, built-in 10K temperature resistor real-time sensing sample temperature, Measurement range 0~ 14pH.

$ 96.00

Operating temperature range 0-70 ° C, temperature sensor, multi-pin connector support, maximum pressure 0.2 bar.

$ 215.00

The tire size of the instrument is Φ 241 +/- 6mm, weight 15.8 +/- 0.2kg, dedicated to marking Coating drying time test, easy to operate, accurate and reliable results.

$ 196.00

Glass sensitive film fully sensing liquid or semi-solid pH value, gel KCL reference solution to ensure long-term use, built-in temperature resistance real-time sensing sample temperature, Measurement range 0~ 14pH, temperature resistance 100K.

$ 109.00

The instrument uses 241 +/- 6mm tire uniform rolling detection, wet film thickness 200um +/- 20um, every 30 seconds, repeability test, accurate determination of non-stick tire drying time, suitable for marking Coating quality control.

$ 231.00