Solution Density Meter

The solution densitometer is based on Archimedes' buoyancy principle, calculating density by measuring the buoyant force exerted by the liquid on an immersed object or the oscillation frequency of a U-shaped tube. It is used to detect solution concentration, purity, and component ratios, and is applied in quality control and production processes in industries such as chemical, food, and petroleum.
Selection
When selecting, consider that the measurement range should cover the sample density interval, the accuracy should meet testing requirements, the temperature compensation function should adapt to the operating environment, the material's corrosion resistance should be compatible with the measured liquid, the ease of operation should align with usage habits, and the calibration method should facilitate daily maintenance.

Terms

Standards

Instruments

Direct reading of solid density volume, density accuracy of 0.001g/cm ³, with temperature compensation and solution compensation functions, support RS-232C interface and built-in battery, convenient for field testing.

$ 317.00

Sensor imported with original, density accuracy of 0.001g/cm ³, support temperature compensation and solution compensation, integrated injection molding measurement table, built-in battery for on-site testing.

$ 399.00

Measurement accuracy of 0.0001g/cm ³, support temperature compensation and solution compensation, can test the density and volume of solid, particle, float and other materials.

$ 503.00

Direct reading of solid density volume of any shape, density accuracy 0.001g/cm ³, with temperature compensation and solution compensation function, built-in battery is convenient for on-site testing.

$ 286.00

The original imported Sensor with density components, density accuracy of 0.001g/cm ³, with temperature compensation and solution compensation functions, support solid particle floating body and other material testing.

$ 338.00

The original imported Sensor with density components, density accuracy of 0.001g/cm ³, with temperature compensation and solution compensation functions, support solid, particle, float and other materials rapid testing.

$ 420.00

Weighing range 0.01g~ 300g, density resolution 0.001g/cm ³, direct reading of any shape of solid density, no manual calculation, with temperature compensation and solution compensation function, built-in battery suitable for field testing.

$ 231.00

The integrated forming large water Tank design has a density accuracy of 0.001g/cm ³, which can quickly measure solids and liquids, support temperature compensation and solution compensation, and is easy and fast to operate.

$ 307.00

The original imported Sensor, density accuracy of 0.0001g/cm ³, support temperature compensation and solution compensation, can test solid, particle, floating body and other materials, with qualified determination and alarm function.

$ 545.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Maximum weighing 210g, density accuracy 0.001g/cm ³, built-in a variety of density reference can be customized settings, support solid and liquid density rack selection, suitable for all kinds of sample density testing.

$ 525.00

High Accuracy weighing system with density accuracy of 0.001g/cm ³, maximum weighing of 210g, built-in density reference program, support for solid and liquid density testing, equipped with level indicator and overload alarm function.

$ 525.00

Density direct reading function can avoid cumbersome calculation, equipped with all stainless steel Density bracket, weighing range 120g, accuracy 0.0001g, suitable for a variety of sample testing.

$ 1151.00

With 0.001g/cm ³ density accuracy and 0.001g weighing accuracy, it supports solid, liquid, powder and Water Absorbency sample testing, and has built-in multiple density reference and direct density display functions.

$ 525.00

Using the Archimedes principle buoyancy method, the density accuracy is 0.0001g/cm ³, the test time is about 5 seconds, the temperature compensation and solution compensation are supported, and the Draft Shield and RS-232C interface are equipped, which is suitable for on-site rapid measurement.

$ 503.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.