The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.
Shear rate 3.84N, sample size only 0.5ml, suitable for a variety of Viscometer models, ensuring High Accuracy measurement and wide applicability.
Range 320~ 320000000mPa · s, support 0.1~ 200rpm stepless speed change, LCD screen can simultaneously display viscosity, shear rate, shear stress and other sets of paraMeters, with a small number of sample adapters only 10-20mL sample volume.
Using 16-bit microcomputer processor and stepper motor high subdivision drive, the whole process of stepless variable speed and stable Rotation speed, Measurement accuracy of +/- 1% F. S, LCD screen can display viscosity, shear rate, shear stress, Rotation speed, temperature and torque and other paraMeters.
Dedicated to 0.1~ 10mPa · s ultra-low viscosity liquid measurement, the sample volume is only 25ml, the cylinder rotor design can accurately calculate the shear rate, easy to sample detailed analysis.
The shear rate is 3.84N, the sample volume is only 1.0ml, suitable for NTV-CAP1 series host, supports a variety of viscosity range measurement, to meet different accuracy requirements.
Rotation speed is accurate and stable with high subdivision drive stepper motor, built-in RTD temperature sensor real-time monitoring sample temperature accuracy 0.1 ℃, support 2000 kinds of shear rate stepless setting and synchronous display Multi-ParaMeter.
Range 20~ 600000mPa · s, repRoducibility +/- 0.5% F. S, LCD screen can display viscosity, shear rate, Rotation speed and other Multi-ParaMeters, support stepless speed control and data printing output.
Shear rate 3.84N, sample volume 0.5ml, suitable for NTV-CAP1 host, suitable for a variety of viscosity range measurement.
Based on the principle of flow between parallel plates, it can quickly and accurately measure inks spread under low shear stress. The sample volume is 0.5 +/- 0.003 cubic centiMeters, and the maximum measurement range of the plate is 9cm. It is suitable for inks flowability evaluation.
Shear rate 7.5N, sample volume only 0.5ml, suitable for NTV-CAP1 host, suitable for small sample viscosity measurement.
Driven by a 16-bit microcomputer processor and a stepper motor, the range is 60 to 60,000,000 mPa · s, and the whole process is continuously variable. The LCD screen displays paraMeters such as viscosity, shear rate, and shear stress.
Rotation speed control with 200 stops and 0.1-200 rpm range, support shear stress and shear rate measurement, can store 10 programs and have data recording function, Measurement accuracy of +/- 1% F.S.
Stepper motor direct drive to ensure accurate Rotation speed, Measurement accuracy of +/- 1% F. S, repRoducibility +/- 0.5% F. S, LCD with backlight display information, can display the maximum viscosity value and exceed the limit alarm.
Range 0~ 100000 mPa · s, repRoducibility +/- 1% F. S, LCD screen can display paraMeters such as viscosity, shear rate, shear stress, Rotation speed, temperature, percentile torque, rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed.