Ultrasonic Moisture Meter

Ultrasonic moisture analyzers measure moisture content by utilizing the relationship between the propagation speed of ultrasonic waves in materials and their moisture levels, as moisture affects both sound velocity and attenuation. They are used for rapid detection of moisture in solids, powders, and other materials, making them suitable for laboratory and production line quality control.

Instruments

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

With microwave and ultrasonic coordinated control function, 250ml container capacity with 1800W adjustable ultrasonic Power, infrared temperature sensor and magnetic stirring system, support a variety of reaction modes to expand applications.

$ 17178.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Equipped with microwave and ultrasonic synergy function, 2000ml large-capacity reactor and 1800W ultrasonic power, support platinum resistance accurate temperature measurement and magnetic stirring, and realize multi-mode chemical reaction control.

$ 15887.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Moisture is measured by thermogravimetry, equipped with 500W high-efficiency halogen ring lamp for uniform heating, Temperature range 40-180 ℃ controllable. 5-inch Touchscreen real-time display of moisture change Linear dispersion, support automatic shutdown and Data storage 100 groups, intuitive operation without supervision.

$ 420.00

With microwave and ultrasonic synergy function, support 500ml reaction vessel, ultrasonic Power 1800W can be fine-tuned, Frequency 20KHz, integrated infrared temperature control and magnetic stirring, suitable for a variety of synthesis conditions to accelerate the reaction.

$ 17178.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.