Dual Thermostatic Electromagnetic Stirrer

The dual constant-temperature electromagnetic stirrer achieves liquid mixing by driving the rotation of magnetic particles inside the container through an electromagnetic field, while maintaining a set temperature in conjunction with a heating module. It is used for constant-temperature stirring of laboratory samples and is commonly applied in scenarios requiring temperature-controlled mixing, such as chemical reactions and paint formulation.
Selection
Confirm that the temperature range and accuracy meet the experimental requirements when selecting. Consider the compatibility between the stirring capacity and the sample container. Check the corrosion resistance of the heating plate material, and pay attention to the stability of the rotational speed and display accuracy. Balance safety protection features with ease of daily maintenance.

Terms

Standards

Instruments

Using electromagnetic force equilibrating Sensor technology, the highest accuracy is 0.01mg, the dual range design covers 210g and 31g, and the micro loading Response is optimized. Automatic calibration and various unit conversions are supported to ensure fast and stable measurement.

$ 1837.00

Brushless DC motor provides 20mN · M torque, stirring speed 100~ 2000rpm, with automatic thermostatic function, Heating power 340W, temperature control accuracy +/- 1 ℃, working plate surface black stainless steel.

$ 186.00

DC brushless motor drive, torque up to 80mN · M, temperature control accuracy +/- 1 ℃, support table and liquid temperature dual control, electronic timing up to 9999 minutes, with dual digital display and intelligent PID temperature control function.

$ 412.00

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Using electromagnetic force equilibrating Sensor, the highest accuracy of 0.01mg, dual range design, fast Response speed, built-in Automatic calibration and a variety of weighing modes, suitable for micro loading.

$ 2300.00

Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.

$ 457.00

Using electromagnetic force equilibrating Sensor, the highest accuracy of 0.01mg, dual range design, optimization of micro sample response, built-in Automatic calibration and a variety of weighing functions, stable time as short as 2.5 seconds.

$ 2220.00

Adopt High Stability Electromagnetic Force Sensor, Dual Range Design, Maximum accuracy 0.01mg, Small Sample Weighing Function, Fast Response Speed, Built-in Multiple Weighing Modes and Fault Detection.

$ 2483.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Using electromagnetic force equilibrating Sensor technology, the highest accuracy of 0.01mg, with dual range function, optimization of micro sample response, built-in Automatic calibration and a variety of weighing modes, transparent windshield design.

$ 2058.00

With liquid and table dual temperature control, effectively reduce temperature overshoot; DC brushless motor supports 50 rpm low speed start, Max.stirring Capacity 5L, temperature control accuracy up to +/- 1 ℃, to ensure stable operation.

$ 298.00

Using electromagnetic force equilibrating Sensor, the highest accuracy of 0.01mg, dual range weighing range 210g/82g, built-in Automatic calibration and micro sample optimization function, Response fast and stable.

$ 2663.00

Driven by DC three-phase brushless motor, temperature control accuracy of +/- 1 ℃, Timer Range 0-9999 minutes, with temperature Rotation speed dual digital display and intelligent PID automatic temperature control function, support table and liquid temperature dual detection.

$ 373.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.