Thermostatic Circulating Oil Bath Tank

The constant temperature circulating oil bath heats up via a heater and uses a circulation pump to drive the flow of heat-conducting oil within a closed system, ensuring uniform and stable temperature inside the bath. It is used in scenarios such as constant-temperature heating of laboratory samples and temperature control in reaction vessels to ensure consistent temperature conditions.
Selection
When selecting, consider that the temperature range must cover experimental requirements, the temperature control accuracy matches sample sensitivity, the tank capacity fits container sizes, pump flow rate affects heat transfer efficiency, and ensure the thermal oil's temperature resistance and chemical compatibility.

Terms

Standards

Instruments

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature range RT + 5~ 200 ℃, temperature fluctuation +/- 0.5 ℃, built-in circulating water pump can output thermostatic water flow, microcomputer intelligent temperature controller with timing and over-temperature alarm function.

$ 532.00

Temperature control accuracy of +/- 0.2 ℃, temperature resolution of 0.1 ℃, support timing and over-temperature alarm function, built-in circulating water pump can output thermostatic water flow, suitable for a variety of thermostatic demand scenarios.

$ 678.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Temperature range up to 300 ℃, Tank volume 36L, using domestic circulation design to ensure temperature uniformity, suitable for a variety of experimental operations.

$ 548.00

Temperature range up to 300 ℃, Temperature Fluctuation +/- 0.5 ℃, equipped with microcomputer intelligent temperature controller, support timing and over-temperature alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.

$ 622.00

Temperature range RT +~ 300 ℃, Tank volume 23L, suitable for distillation, drying, condensing and impregnation and other experimental operations, to meet a variety of chemical and biological experimental needs.

$ 451.00

With water and oil dual-use function, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, equipped with multiple Safety protection devices.

$ 677.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

With the function of water-oil dual-use, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field and support the establishment of a second thermostatic field for external circulation.

$ 564.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, support external circulation to establish a second thermostatic field, built-in multiple Safety protection devices.

$ 798.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
The difference between a wire-wound rod coater and an extrusion coating rod
This article primarily compares the technical differences between wire-wound and extrusion coating rods. Although they are interchangeable in most scenarios, there are subtle variations in liquid loading capacity due to their distinct groove principles.