Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.
Designed for Ammonia Gas Sensitive Compound ElectRode, it provides a stable reference potential to ensure accurate measurement. The Encasement specification is 250ml, which is suitable for long-term monitoring applications.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.
Measurement range covers 0.05-1000 mg/L, glass sensitive film design, temperature range 5-45 ℃, equipped with Q9 connector to ensure stable detection of ammonia nitrogen content.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.
Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Composite ElectRode design, with 60mL reference filler and calibrated solution, built-in BNC connector, support for replaceable membranes for easy maintenance and long-term use.
Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.
Suitable for Ammonia Gas sensing electRode maintenance, capacity 480mL, Water Hardness Detection dedicated to ensure ElectRode performance stability, prolong service life.