Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.
The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.
Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.
Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.
Measurement accuracy +/- 2%, equipped with 5 calibrated oils to ensure measurement accuracy, as a special accessory for cone-plate viscoMeter to achieve stability testing.
The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.
Provides accurate viscosity values of 5.7cp, 400ml per bottle for Viscometer calibrated measurement Stability and Reliability.
Using electromagnetic force equilibrating Sensor, accuracy of 1mg, Stabilization time ≤ 6s, with RS232 Communication interface, counting function and density measurement and other practical functions.
Range 5-50p, accuracy of +/- 2%, equipped with 5 kinds of special calibrated oil to ensure measurement accuracy, as the core component of cone-plate viscoMeter to ensure test Stability.
Shear rate 3.84N, sample size only 0.5ml, suitable for a variety of Viscometer models, ensuring High Accuracy measurement and wide applicability.
High Accuracy Electromagnetic Force Sensor, dynamic temperature compensation technology to ensure accuracy, repeatability error +/- 2mg, standard RS232 interface can transfer data directly to Excel.
High Accuracy Electromagnetic Force Sensor, Capacity 520g, readability accuracy 0.1mg, OLED display and Draft Shield static elimination design, support external calibrating and multiple unit switching.
High Accuracy Electromagnetic Force Sensor, repeatability error +/- 1mg, Draft Shield static elimination design, support for external calibrating and multiple weighing units for special application needs.
High Accuracy Electromagnetic Force Sensor, Capacity 320g, readability 0.1mg, support automatic internal calibrating and multiple weighing units, equipped with transportation protection devices.
High Accuracy Electromagnetic Force Sensor, repeatability error +/- 0.2mg, dynamic temperature compensation technology to ensure weighing accuracy, reaction time is less than 3 seconds, support a variety of unit weighing.