UV Light SpectroPhotoMeter

UV spectrophotometers utilize the absorption characteristics of substances to ultraviolet light, analyzing component concentrations by measuring sample absorbance. In industries such as coatings and inks, they are used to detect dye purity, solvent residues, and for product quality control.
Selection
When selecting, consider a wavelength range covering 190-1100 nm, with a bandwidth of less than 2 nm to ensure resolution. Pay attention to baseline flatness and stray light indicators, and match the cuvette type. Verify the instrument's stability and ease of operation, ensuring compatibility with industry testing standards.

Terms

Standards

Instruments

1200L/mm UV dedicated grating and proportional double beam of light design, stray light ≤ 0.03% T, equipped with 10cm sample holder and automatic octet cell, support wavelength scanning and a variety of test modes.

$ 3623.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

Adopt 1200L/mm UV special grating and imported photoelectric converter, stray light ≤ 0.03% T, Wavelength range 190~ 1100nm, with automatic correction wavelength error function, support 10cm sample holder to meet special needs.

$ 2252.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octagonal cell sample holder to improve test efficiency, Wavelength range 190~ 1100nm coverage of a wide range of applications.

$ 3268.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

Using Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can store 100 standard Linear dispersion and 200 data, supports a variety of Cuvette and direct printouts.

$ 1300.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 1.8nm, can store 100 standard Linear dispersion and 200 data, support a variety of Cuvette and direct printouts.

$ 1300.00

Equipped with a large screen LCD graphic display, can accommodate 5-100mm Cuvette, wavelength Precision +/- 0.3nm, with automatic wavelength Adjustment, supports multiple test modes including Light spectrum scanning and kinetic testing.

$ 1397.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional dual beam of light design supports automatic octet cell, Wavelength range 190~ 1100nm, with professional wavelength correction function.

$ 2978.00

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.