Eddy-Current Testing Apparatus

The eddy current tester utilizes the principle of electromagnetic induction. When alternating current passes through the probe coil, it induces eddy currents on the surface of conductive materials. Material defects or changes in thickness alter the distribution of the eddy currents, and anomalies are identified by detecting changes in the coil impedance. It is used to detect surface cracks, corrosion, and coating thickness in metals, commonly applied in aerospace, automotive manufacturing, and pipeline maintenance.
Selection
When selecting an eddy current tester, consider the electrical conductivity of the material to be tested, the required penetration depth, and the type of defects. High frequencies are suitable for surface inspection, while low frequencies are used for deep-seated issues. Choose between portable or fixed equipment based on the application environment, ensuring the probe size matches the inspection area. Refer to standards such as ASTM E309, verify the instrument’s accuracy and ease of calibration, and align with budget and operational requirements.

Terms

Standards

Instruments

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, error +/- 3%, support single and continuous Measurement mode, automatic identification of matrix material and memory calibrated value, easy to operate.

$ 401.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.

$ 275.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.

$ 525.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.

$ 419.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support continuous single two Measurement mode, with automatic statistics and storage function, metal shell anti-interference.

$ 425.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500μm, resolution 10μm, wear-resistant hard metal probe and Automatic calibration memory function, support USB data communication and automatic shutdown.

$ 240.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, resolution 0.1μm, with 500 sets of Data storage, over limit alarm and automatic shutdown function, split Probe design is easy to operate on site.

$ 280.00

Integrated magnetic Induction and eddy Current dual technology, automatic identification of the substrate and conversion, Measurement range 0-1500μm, accuracy +/- 2%, Probe life more than 500,000 times, adapt to complex environment.

$ 227.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500μm, support continuous single two Measurement mode, with 500 sets of data storage and thermal printing function, the error is only +/- 3%.

$ 385.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.